From: Travis Stratman In-Reply-To: <49B99153.2010505@domain.hid> References: <1236892358.29394.296.camel@domain.hid> <49B99153.2010505@domain.hid> Date: Thu, 12 Mar 2009 18:30:17 -0500 Message-Id: <1236900617.29394.346.camel@domain.hid> Mime-Version: 1.0 Content-Type: text/plain Content-Transfer-Encoding: 7bit Subject: Re: [Xenomai-help] Application question List-Id: Help regarding installation and common use of Xenomai List-Unsubscribe: , List-Archive: List-Post: List-Help: List-Subscribe: , To: Gilles Chanteperdrix Cc: Xenomai Help List Thanks Gilles. On Thu, 2009-03-12 at 23:48 +0100, Gilles Chanteperdrix wrote: > > > > The target for this application would be an Atmel AT91SAM9260 processor > > or AT91SAM9G20 (9260 at 400 MHz essentially). The main constraint is > > that the ADC in the processor must be sampled at 200K samples/sec which > > gives a period of about 5 us. This sampling happens in bursts of 50 to > > several hundreds of samples (so at most 2 ms for this task). Once the > > data is analyzed, a value is set on a DAC. Once the value has been set > > 10s to 100s of ms go by before the cycle starts over again with sampling > > and analysis. > > > > The timing on the sampling is pretty critical, though a little jitter > > might be acceptable at times. In general there shouldn't be much else > > going on in the background on the board. The ADC block is rated at a max > > 312K samples / second. > > > > The 5 us sampling period is too fast to schedule the sampling as a > > periodic task. But, since the actual sample burst time is under 1 ms > > most of the time I was thinking that I might be able to schedule a > > thread to take a certain number of samples in one task, inserting delays > > between each sample to get the timing right. > > > > Polling during the time of the acquisition seems to be your best chance > on an ARM. However, one issue remain or maybe I did not understand > correctly your explanation: how do you wake up on time for the beginning > of this acquisition? Wake-up jitter is pretty high on ARM, even with > FCSE, you can count on something like 100us. > I'm not completely sure at this point... a customer has presented this problem and I'm looking at the feasibility of it for now. I think that an external flag will be read (some PIO line, possibly an interrupt) that signals when a motor has settled down at which point calibration begins again. I don't think that this timing is nearly as critical as the sampling rate. I asked him to provide further information on it just in case. At this point I think the best thing for me to do at this point would be to do some testing. I also noticed that the ADC seems to support scheduling triggers using a timer/counter output and transferring samples to a DMA buffer... this would be ideal if I can get it to work right. Thanks, TAS