Return-path: Received: from he.sipsolutions.net ([78.46.109.217]:46479 "EHLO sipsolutions.net" rhost-flags-OK-OK-OK-OK) by vger.kernel.org with ESMTP id S1751856Ab1CYNFH (ORCPT ); Fri, 25 Mar 2011 09:05:07 -0400 Subject: Re: Aggregation problem with rt2800 AP and Intel 5100 STA From: Johannes Berg To: Helmut Schaa Cc: Emmanuel Grumbach , linux-wireless@vger.kernel.org In-Reply-To: <201103251355.55824.helmut.schaa@googlemail.com> References: <201103232358.29966.helmut.schaa@googlemail.com> <201103251208.22473.helmut.schaa@googlemail.com> <1301052224.3827.2.camel@jlt3.sipsolutions.net> <201103251355.55824.helmut.schaa@googlemail.com> Content-Type: text/plain; charset="UTF-8" Date: Fri, 25 Mar 2011 14:06:55 +0100 Message-ID: <1301058415.20631.1.camel@jlt3.sipsolutions.net> Mime-Version: 1.0 Sender: linux-wireless-owner@vger.kernel.org List-ID: On Fri, 2011-03-25 at 13:55 +0100, Helmut Schaa wrote: > So far the tx status as returned by the device look correct. I printed the > sequence numbers of failed AMPDU subframes and had a second device capturing > the traffic and compared them. > > But I noticed that there still appear holes from time to time that cause the > strange Intel driver stuck problem (which is really really strange and IMHO > the driver has a problem too). And it is not necessarily PS related. > > Johannes, what happens if a frame gets dropped on its way though the tx path > after getting a seqnr assigned? That would cause a hole in the sequence number > series without the chance to get a IEEE80211_TX_STAT_AMPDU_NO_BACK tx status. Yeah that's correct, try not to do that :) It's one of the reasons the Intel driver assigns its own sequence numbers to AMPDU frames (the other being some odd seqno/queue place match requirement.) johannes