From: Nikolaus Schulz Date: Wed, 08 Feb 2012 17:56:08 +0000 Subject: [lm-sensors] [PATCH 1/4] hwmon: (f75375s) Fix automatic pwm mode setting for F75373 & F75375 Message-Id: <1328723771-22163-2-git-send-email-mail@microschulz.de> List-Id: MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: lm-sensors@vger.kernel.org From: Nikolaus Schulz In order to enable temperature mode aka automatic mode for the F75373 and F75375 chips, the two FANx_MODE bits in the fan configuration register need be set to 01, not 10. Signed-off-by: Nikolaus Schulz Cc: stable@kernel.org --- drivers/hwmon/f75375s.c | 2 +- 1 files changed, 1 insertions(+), 1 deletions(-) diff --git a/drivers/hwmon/f75375s.c b/drivers/hwmon/f75375s.c index eedf574..c81ad45 100644 --- a/drivers/hwmon/f75375s.c +++ b/drivers/hwmon/f75375s.c @@ -369,7 +369,7 @@ static int set_pwm_enable_direct(struct i2c_client *client, int nr, int val) fanmode |= (3 << FAN_CTRL_MODE(nr)); break; case 2: /* AUTOMATIC*/ - fanmode |= (2 << FAN_CTRL_MODE(nr)); + fanmode |= (1 << FAN_CTRL_MODE(nr)); break; case 3: /* fan speed */ break; -- 1.7.9 _______________________________________________ lm-sensors mailing list lm-sensors@lm-sensors.org http://lists.lm-sensors.org/mailman/listinfo/lm-sensors