From: Ian Campbell Subject: Re: [PATCH 0/3] xen: fix various wallclock problems Date: Mon, 15 Oct 2012 10:26:57 +0100 Message-ID: <1350293217.18058.11.camel@zakaz.uk.xensource.com> References: <1350046634-2462-1-git-send-email-david.vrabel@citrix.com> <50784462.3060203@citrix.com> Mime-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit Return-path: In-Reply-To: <50784462.3060203@citrix.com> List-Unsubscribe: , List-Post: List-Help: List-Subscribe: , Sender: xen-devel-bounces@lists.xen.org Errors-To: xen-devel-bounces@lists.xen.org To: David Vrabel Cc: "xen-devel@lists.xen.org" , Konrad Rzeszutek Wilk List-Id: xen-devel@lists.xenproject.org On Fri, 2012-10-12 at 17:25 +0100, David Vrabel wrote: > On 12/10/12 13:57, David Vrabel wrote: > > This series (with some toolstack updates) corrects a number of cases > > where a guest can see an incorrect wallclock time. > > > > 1. Systems with NTP won't periodically synchronize the hardware RTC so > > the wallclock may be incorrect after a reboot. > > > > 2. The wallclock is always ~500 ms behind the correct time. > > > > 3. If the system time was stepped and NTP isn't synchronized yet, the > > wallclock will still have the incorrect time. The fix for this > > requires the toolstack to synchronize the wallclock -- patch #3 > > provides the mechanism for this. > > These tables should help. > > Before: > > | Updates > Process | System Time? Xen Wallclock? Hardware Clock? > ------------------------------------------------------------- > date -s | X > hwclock -w | X > ntpd | X X[*] > ntpdate | X What does the equivalent table for native look like? Is the "updated hardware clock" column in that caseis union of xen wallclock and hardware clock columns here? Ian.