From: Hannes Reinecke Subject: [PATCH] megaraid_sas: Fallback to older scanning if not disks are found Date: Fri, 15 Jan 2016 15:13:13 +0100 Message-ID: <1452867193-41266-1-git-send-email-hare@suse.de> Return-path: Received: from mx2.suse.de ([195.135.220.15]:47908 "EHLO mx2.suse.de" rhost-flags-OK-OK-OK-OK) by vger.kernel.org with ESMTP id S1752987AbcAOONR (ORCPT ); Fri, 15 Jan 2016 09:13:17 -0500 Sender: linux-scsi-owner@vger.kernel.org List-Id: linux-scsi@vger.kernel.org To: Sumit Saxena Cc: Kashyap Desai , megaraidlinux.pdl@avagotech.com, "Martin K. Petersen" , James Bottomley , linux-scsi@vger.kernel.org, Hannes Reinecke commit 21c9e160a51383d4cb0b882398534b0c95c0cc3b implemented a new driver lookup using the MR_DCMD_LD_LIST_QUERY firmware command. However, this command might not work properly on older firmware, causing the command to return no drives instead of an error. This causes a regression on older firmware as the driver will no longer detect any drives. This patch checks if MR_DCMD_LD_LIST_QUERY return no drives, and falls back to the original method if so. Signed-off-by: Hannes Reinecke --- drivers/scsi/megaraid/megaraid_sas_base.c | 4 ++++ 1 file changed, 4 insertions(+) diff --git a/drivers/scsi/megaraid/megaraid_sas_base.c b/drivers/scsi/megaraid/megaraid_sas_base.c index f97ec34..79dff70 100644 --- a/drivers/scsi/megaraid/megaraid_sas_base.c +++ b/drivers/scsi/megaraid/megaraid_sas_base.c @@ -4107,6 +4107,10 @@ megasas_ld_list_query(struct megasas_instance *instance, u8 query_type) ret = megasas_issue_polled(instance, cmd); tgtid_count = le32_to_cpu(ci->count); + if (tgtid_count == 0) { + /* No drives found, try the older LD list DCMD */ + ret = 1; + } if ((ret == 0) && (tgtid_count <= (instance->fw_supported_vd_count))) { memset(instance->ld_ids, 0xff, MEGASAS_MAX_LD_IDS); -- 1.8.5.6