From: Wolfgang Denk Date: Mon, 22 Aug 2005 18:14:07 +0200 Subject: [U-Boot-Users] loads command cannot transfer srec file In-Reply-To: Your message of "Tue, 23 Aug 2005 01:18:55 +1000." <1124723935.53efd4dcS3092131@student.rmit.edu.au> Message-ID: <20050822161407.3F7E6352B0C@atlas.denx.de> List-Id: MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: u-boot@lists.denx.de In message <1124723935.53efd4dcS3092131@student.rmit.edu.au> you wrote: > I am now using Kermit for the serial communication. But still i am having t= > he same problem. *Please* use shorter lines. And *please* read the documentation, and then read it again. Kermit is fine when using the "loadb" command which implements kermit binary protocol. But for "loads" the documentation says to use "cu", doesn't it? > When i use loads 40000 i get the output as > ## Ready for S-Record download ... > and then the system seems to do nothing. It does something. It sits there in the serial driver waiting for you to send S-Records over the serial line. > When i use loadb > ##Ready for binary (kermit) download to 0xA0800000 at 115200 bps.. > and then the system seems to do nothing. It does something. It sits there in the serial driver waiting for you to send kermit binary protocol data over the serial line. > Please guide me what could be the reason for this Incorrect use. > -----Original Message----- > From: Wolfgang Denk > To: "Swapnil Ashok Narkhede" > Date: Mon, 22 Aug 2005 14:06:27 +0200 > Subject: Re: [U-Boot-Users] loads command cannot transfer srec file=20 And please don't top post / full quote. Read the netiquette. Best regards, Wolfgang Denk -- Software Engineering: Embedded and Realtime Systems, Embedded Linux Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd at denx.de Looks clean and obviously correct to me, but then _everything_ I write always looks obviously correct to me. - Linus Torvalds in