From: khali@linux-fr.org (Jean Delvare) Date: Tue, 28 Mar 2006 20:34:53 +0000 Subject: [lm-sensors] [PATCH] New sensors program patch for SMSC47M192 Message-Id: <20060328223453.cff5b061.khali@linux-fr.org> List-Id: References: In-Reply-To: MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: lm-sensors@vger.kernel.org Hi Hartmut, Sorry for the late reply... > > For temperatures, the Linux 2.4 standard is VALUE(1) for the high limit > > and VALUE(2) for the low limit. This still doesn't affect your Linux 2.6 > > Ok, I've changed that for the temperatures. Does the same comment apply > also to voltages? No, voltages have it the other way around. Don't ask ;) > Otherwise I hope I've included all your comments. Looks all OK, I just applied it to lm_sensors CVS. Thanks a lot for the good work Hartmut! -- Jean Delvare