From: "Mark M. Hoffman" Date: Mon, 18 Feb 2008 03:07:31 +0000 Subject: Re: [lm-sensors] [PATCH] coretemp: Add TjMax detection for Message-Id: <20080218030731.GF2916@jupiter.solarsys.private> List-Id: References: <478FE918.9030804@assembler.cz> In-Reply-To: <478FE918.9030804@assembler.cz> MIME-Version: 1.0 Content-Type: text/plain; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable To: lm-sensors@vger.kernel.org Hi Rudolf: * Rudolf Marek [2008-02-17 22:59:39 +0100]: > -----BEGIN PGP SIGNED MESSAGE----- > Hash: SHA1 >=20 > Hi Jean, >=20 > Thanks for the review. Here it comes updated. I managed to get to test th= is on > core2 system: >=20 > coretemp-isa-0000 > Adapter: ISA adapter > Core 0: +50.0=B0C (high =3D +80.0=B0C, crit =3D +100.0=B0C) >=20 > coretemp-isa-0001 > Adapter: ISA adapter > Core 1: +51.0=B0C (high =3D +80.0=B0C, crit =3D +100.0=B0C) >=20 > Seems to work ;) >=20 > Hello, >=20 > Following patch will finally solve the detection of Intel Mobile CPUs whi= ch > share same CPUID with Desktop/Server CPUs. We need this information to te= st > some bit so we know if TjMax is 100C or 85C. Intel claims this works for = mobiles > only, respect that and set for desktops the TjMax to 100C. Intel provided= some > table on their wiki based on my chat with them at: > http://softwarecommunity.intel.com/isn/Community/en-US/forums/30247249/Sh= owThread.aspx#30247249 >=20 > Signed-off-by: Rudolf Marek Applied to hwmon-2.6.git/testing, thanks. --=20 Mark M. Hoffman mhoffman@lightlink.com _______________________________________________ lm-sensors mailing list lm-sensors@lm-sensors.org http://lists.lm-sensors.org/mailman/listinfo/lm-sensors