From: Wolfgang Denk Date: Tue, 24 Feb 2009 22:29:37 +0100 Subject: [U-Boot] CONFIG_SYS_HZ: Please revert breaking net commit In-Reply-To: <49A44806.9050902@vollmann.ch> References: <49A44806.9050902@vollmann.ch> Message-ID: <20090224212937.913E7832E43F@gemini.denx.de> List-Id: MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: u-boot@lists.denx.de Dear Detlef Vollmann, In message <49A44806.9050902@vollmann.ch> you wrote: > > commit 49f3bdbba8071f56d950a9498b6cdb998b35340a ... > This commit breaks *silently* all boards that don't return > milliseconds from get_timer, i.e. have a different value for > CONFIG_SYS_HZ than 1000. No, this is not true. All these boards ARE already broken because they use anincorrect timer setup. The patch just makes the problem visible. > I'm open to any discussion about removing CONFIG_SYS_HZ, but > if it is removed, it should be removed explicitely, and not > just silently ignored. There is no need in the code to use CONFIG_SYS_HZ, because the code just used get_timer() as specified, i. e. it expects correct behaviour. If your implementation is broken, you should fix your implementation. BTW: how comes it takes you nearly half a year to detect this? > So I see following reasons to revert the above commit: > - silently breaks existing boards These boards were already broken before. > - silently ignores a still valid CONFIG setting It does not ignore it. It does not need it, because it is specified that get_timer() uses milisecond resolution. > - bad programming style anyway: even if CONFIG_SYS_HZ would > go away, there should be some internal define that should > be used in code I don't understand what you mean. > - the intended benefit 'millisecond granularity for network-related > timeouts' can be achieved while still keeping CONFIG_SYS_HZ Instead of complaining about a patch that was discussed and cehcekd in many months ago you could rather spend your time on fixing your broken boards. Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd at denx.de This is now. Later is later.