From: Philippe De Muyter Date: Tue, 10 Aug 2010 18:12:53 +0200 Subject: [U-Boot] [PATCHv2 CFI flash]: Workaround for Numonyx Axcell?P33/P30 256-Mbit 65nm bug In-Reply-To: <201008101728.59679.sr@denx.de> References: <20100623115701.GA17625@frolo.macqel> <201008091552.03923.sr@denx.de> <20100809154603.GA3594@frolo.macqel> <201008101728.59679.sr@denx.de> Message-ID: <20100810161253.GA16134@frolo.macqel> List-Id: MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: u-boot@lists.denx.de On Tue, Aug 10, 2010 at 05:28:59PM +0200, Stefan Roese wrote: > Hi Philippe, > > one more thing: > > On Monday 09 August 2010 17:46:03 Philippe De Muyter wrote: > > Here is the excerpt from the errata : > > > > Workaround: If the interval between 60h and its subsequent command > > can be guaranteed within 20?s, Option I is recommended, > > otherwise Option II (involves hardware) should be selected. > > Option I: The table below lists the detail command sequences: > > Command > > Data bus Address bus Remarks > > Sequence > > 1 90h Block Address > > Read Lock Status > > 2 Read Block Address + 02h > > (2)(3) (1) > > 3 60h Block Address > > (2)(3) (1) Lock/Unlock/RCR > > Configuration 4 D0h/01h/03h Block Address > > Notes: > > (1) Block Address refers to RCR configuration data only when the 60h > > command sequence is used to set RCR register combined with 03h > > subsequent command. > > (2) For the third and fourth command sequences, the Block Address must > > be the same. > > (3) The interval between 60h command and its subsequent D0h/01h/2Fh/03h > > commands should be less than 20?s. > > Please add this workaround text from the errata to the commit text in your > next patch version. This makes things easier - no need to search for the > errata. OK Philippe