From: Wolfgang Denk Date: Wed, 13 Apr 2011 22:50:13 +0200 Subject: [U-Boot] [PATCHv2] fsl_ddr: Don't use full 64-bit divides on 32-bit PowerPC In-Reply-To: <1298478920-22044-1-git-send-email-Kyle.D.Moffett@boeing.com> References: <1298478920-22044-1-git-send-email-Kyle.D.Moffett@boeing.com> Message-ID: <20110413205013.E4FD014F02E@gemini.denx.de> List-Id: MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: u-boot@lists.denx.de Dear Kyle Moffett, In message <1298478920-22044-1-git-send-email-Kyle.D.Moffett@boeing.com> you wrote: > The current FreeScale MPC-8xxx DDR SPD interpreter is using full 64-bit > integer divide operations to convert between nanoseconds and DDR clock > cycles given arbitrary DDR clock frequencies. ... > +/* To avoid 64-bit full-divides, we factor this here */ > +#define ULL_2e12 2000000000000ULL > +#define UL_5pow12 244140625UL > +#define UL_2pow13 (1UL << 13) > + > +#define ULL_8Fs 0xFFFFFFFFULL We don't allow CamelCaps macro names. Macros are all caps, please. Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd at denx.de Man is the best computer we can put aboard a spacecraft ... and the only one that can be mass produced with unskilled labor. - Wernher von Braun