From: Jean Delvare Date: Sun, 20 Apr 2014 12:40:06 +0000 Subject: [lm-sensors] [PATCH] hwmon: Document temp[1-*]_min_hyst sysfs attribute Message-Id: <20140420144006.17c4f79e@endymion.delvare> List-Id: MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: lm-sensors@vger.kernel.org The temp[1-*]_min_hyst sysfs attribute is already implemented by 3 hwmon drivers (adt7x10, lm77 and lm92) but was missing from the standard interface. Also add temp[1-*]_lcrit_hyst for consistency, even though no driver implement that one for the time being. Signed-off-by: Jean Delvare Cc: Guenter Roeck --- Documentation/hwmon/sysfs-interface | 14 ++++++++++++++ 1 file changed, 14 insertions(+) --- linux-3.15-rc1.orig/Documentation/hwmon/sysfs-interface 2014-03-31 05:40:15.000000000 +0200 +++ linux-3.15-rc1/Documentation/hwmon/sysfs-interface 2014-04-20 14:32:45.854170603 +0200 @@ -327,6 +327,13 @@ temp[1-*]_max_hyst from the max value. RW +temp[1-*]_min_hyst + Temperature hysteresis value for min limit. + Unit: millidegree Celsius + Must be reported as an absolute temperature, NOT a delta + from the min value. + RW + temp[1-*]_input Temperature input value. Unit: millidegree Celsius RO @@ -362,6 +369,13 @@ temp[1-*]_lcrit Temperature critical min Unit: millidegree Celsius RW +temp[1-*]_lcrit_hyst + Temperature hysteresis value for critical min limit. + Unit: millidegree Celsius + Must be reported as an absolute temperature, NOT a delta + from the critical min value. + RW + temp[1-*]_offset Temperature offset which is added to the temperature reading by the chip. -- Jean Delvare SUSE L3 Support _______________________________________________ lm-sensors mailing list lm-sensors@lm-sensors.org http://lists.lm-sensors.org/mailman/listinfo/lm-sensors