From: Jean Delvare Date: Thu, 22 May 2014 16:27:56 +0000 Subject: Re: [lm-sensors] [PATCH] i8k: increase fan limit to 3 Message-Id: <20140522182756.04afd351@endymion.delvare> List-Id: References: <1400725168-21358-1-git-send-email-fbl@redhat.com> <537D6FC8.5000105@roeck-us.net> <20140522082831.GA16167@alpha.franken.de> <20140522151259.GC1001@roeck-us.net> In-Reply-To: <20140522151259.GC1001@roeck-us.net> MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: Guenter Roeck Cc: Thomas Bogendoerfer , Flavio Leitner , linux-kernel@vger.kernel.org, Arnd Bergmann , Flavio Leitner , lm-sensors@lm-sensors.org On Thu, 22 May 2014 08:12:59 -0700, Guenter Roeck wrote: > On Thu, May 22, 2014 at 10:28:31AM +0200, Thomas Bogendoerfer wrote: > > On Wed, May 21, 2014 at 08:32:24PM -0700, Guenter Roeck wrote: > > > On 05/21/2014 07:19 PM, Flavio Leitner wrote: > > > >From: Flavio Leitner > > > > > > > >It is possible to increase left fan speed on a > > > >DELL Precision 490n system up to 3. > > > > > > > > value fan rpm > > > > 1 35460 > > > > 2 64740 > > > > 3 78510 > > > > > > > Guess the speed factor 30 doesn't apply here. > > > > on my vostro 1720 value 3 is default value and it looks like > > it's sort of an auto mode. > > > > BTW. the only fan in the system is on the left side, but shows up as > > RigthFan. Wouldn't it be better to simply number the fans and let the > > "real" labeling be done via sensors.conf ? > > > I agree. Jean, any comments ? Is it ok to drop the fan labels ? Yes it is, I had that it mind already, just I don't have the time to do it. -- Jean Delvare SUSE L3 Support _______________________________________________ lm-sensors mailing list lm-sensors@lm-sensors.org http://lists.lm-sensors.org/mailman/listinfo/lm-sensors