From: u.kleine-koenig@pengutronix.de (Uwe =?iso-8859-1?Q?Kleine-K=F6nig?=) Date: Thu, 17 Jul 2014 20:42:37 +0200 Subject: [PATCH v2] i2c: efm32: correct namespacing of location property In-Reply-To: <20140717134000.GK2740@katana> References: <1405066940-12919-1-git-send-email-u.kleine-koenig@pengutronix.de> <1405068614-14279-1-git-send-email-u.kleine-koenig@pengutronix.de> <20140717134000.GK2740@katana> Message-ID: <20140717184237.GX11056@pengutronix.de> To: linux-arm-kernel@lists.infradead.org List-Id: linux-arm-kernel.lists.infradead.org On Thu, Jul 17, 2014 at 03:40:00PM +0200, Wolfram Sang wrote: > On Fri, Jul 11, 2014 at 10:50:14AM +0200, Uwe Kleine-K?nig wrote: > > Olof Johansson pointed out that usually the company name is picked as > > namespace prefix to specific properties. So expect "energymicro,location" > > but fall back to the previously introduced name "efm32,location". > > > > Cc: Olof Johansson > > Signed-off-by: Uwe Kleine-K?nig > > Applied to for-next, thanks! If you think this is better suited in > for-current, let me know. I'm not in a hurry. If you take it it's fine for me. (BTW, I'm not sure i fI understand your branch naming. for-next means "targeting the next merge window" and for-current means "targeting the next release"? So for-next currently means 3.17-rc1?) Thanks Uwe -- Pengutronix e.K. | Uwe Kleine-K?nig | Industrial Linux Solutions | http://www.pengutronix.de/ |