Return-Path: Date: Wed, 8 Apr 2015 18:30:34 +0300 From: Vlad Dogaru To: Irina Tirdea Cc: Jonathan Cameron , linux-iio@vger.kernel.org, linux-kernel@vger.kernel.org, Hartmut Knaack Subject: Re: [PATCH] iio: pressure: bmp280: fix temp compensation Message-ID: <20150408153034.GA23781@vdogaru> References: <1428506772-23710-1-git-send-email-irina.tirdea@intel.com> MIME-Version: 1.0 Content-Type: text/plain; charset=us-ascii In-Reply-To: <1428506772-23710-1-git-send-email-irina.tirdea@intel.com> List-ID: On Wed, Apr 08, 2015 at 06:26:12PM +0300, Irina Tirdea wrote: > Temperature reads on bmp280 device always return 0, > due to a missing step in the compensation formula > (data->tfine is never initialized). > > Initialize data->tfine value so we get correct > temperature and pressure values. > > Signed-off-by: Irina Tirdea Reviewed-by: Vlad Dogaru Nice catch, this must have been lost during a refactoring. Thanks, Vlad