From: broonie@kernel.org (Mark Brown) Date: Fri, 15 Jul 2016 13:50:39 +0100 Subject: "coupled" regulator support In-Reply-To: <20160715200113.0f3cd823@xhacker> References: <20160715200113.0f3cd823@xhacker> Message-ID: <20160715125039.GI30372@sirena.org.uk> To: linux-arm-kernel@lists.infradead.org List-Id: linux-arm-kernel.lists.infradead.org On Fri, Jul 15, 2016 at 08:01:13PM +0800, Jisheng Zhang wrote: > regR can only be set to v1 if devA and devB all call for set voltage to v1 > regR can set to v2 if devA or devB call for set voltage to v2 > To support this situation, I'd like to add flag to regulator structure and > patch regulator_check_consumers() to check whether we are safe to set the vol Surely this is just what normal set voltage calls do? If devA says set_voltage(v1, v2) but devB still has set_voltage(v2, v2) then we will leave the voltage at v2, we'll only allow it to be set to v1 if both consumers agree that this is a valid voltage. It feels like there's something else going on here that I'm missing? -------------- next part -------------- A non-text attachment was scrubbed... Name: signature.asc Type: application/pgp-signature Size: 473 bytes Desc: not available URL: