From: tasleson Date: Thu, 2 Feb 2017 16:59:22 +0000 (UTC) Subject: master - lvmdbusd: pv.py, remove duplicate code Message-ID: <20170202165922.E26606024A@fedorahosted.org> List-Id: To: lvm-devel@redhat.com MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit Gitweb: http://git.fedorahosted.org/git/?p=lvm2.git;a=commitdiff;h=681d69c70ae70dffa9d21bfd82e1e9821371ee82 Commit: 681d69c70ae70dffa9d21bfd82e1e9821371ee82 Parent: a010cede6e69fcb9301d0b1f4e282a2b04d15430 Author: Tony Asleson AuthorDate: Wed Feb 1 16:51:00 2017 -0600 Committer: Tony Asleson CommitterDate: Wed Feb 1 16:51:00 2017 -0600 lvmdbusd: pv.py, remove duplicate code Move similar code to common functions, less is more! --- daemons/lvmdbusd/pv.py | 65 ++++++++++++++++++----------------------------- 1 files changed, 25 insertions(+), 40 deletions(-) diff --git a/daemons/lvmdbusd/pv.py b/daemons/lvmdbusd/pv.py index 95047d1..fe32143 100644 --- a/daemons/lvmdbusd/pv.py +++ b/daemons/lvmdbusd/pv.py @@ -135,23 +135,30 @@ class Pv(AutomatedProperties): def _remove(pv_uuid, pv_name, remove_options): # Remove the PV, if successful then remove from the model # Make sure we have a dbus object representing it - dbo = cfg.om.get_object_by_uuid_lvm_id(pv_uuid, pv_name) + Pv.validate_dbus_object(pv_uuid, pv_name) + rc, out, err = cmdhandler.pv_remove(pv_name, remove_options) + Pv.handle_execute(rc, out, err) + return '/' - if dbo: - rc, out, err = cmdhandler.pv_remove(pv_name, remove_options) - if rc == 0: - cfg.load() - else: - # Need to work on error handling, need consistent - raise dbus.exceptions.DBusException( - PV_INTERFACE, - 'Exit code %s, stderr = %s' % (str(rc), err)) + @staticmethod + def handle_execute(rc, out, err): + if rc == 0: + cfg.load() else: + # Need to work on error handling, need consistent + raise dbus.exceptions.DBusException( + PV_INTERFACE, + 'Exit code %s, stderr = %s' % (str(rc), err)) + + @staticmethod + def validate_dbus_object(pv_uuid, pv_name): + dbo = cfg.om.get_object_by_uuid_lvm_id(pv_uuid, pv_name) + if not dbo: raise dbus.exceptions.DBusException( PV_INTERFACE, 'PV with uuid %s and name %s not present!' % (pv_uuid, pv_name)) - return '/' + return dbo @dbus.service.method( dbus_interface=PV_INTERFACE, @@ -168,22 +175,11 @@ class Pv(AutomatedProperties): @staticmethod def _resize(pv_uuid, pv_name, new_size_bytes, resize_options): # Make sure we have a dbus object representing it - dbo = cfg.om.get_object_by_uuid_lvm_id(pv_uuid, pv_name) + Pv.validate_dbus_object(pv_uuid, pv_name) - if dbo: - rc, out, err = cmdhandler.pv_resize(pv_name, new_size_bytes, + rc, out, err = cmdhandler.pv_resize(pv_name, new_size_bytes, resize_options) - if rc == 0: - cfg.load() - else: - raise dbus.exceptions.DBusException( - PV_INTERFACE, - 'Exit code %s, stderr = %s' % (str(rc), err)) - else: - raise dbus.exceptions.DBusException( - PV_INTERFACE, - 'PV with uuid %s and name %s not present!' % - (pv_uuid, pv_name)) + Pv.handle_execute(rc, out, err) return '/' @dbus.service.method( @@ -201,21 +197,10 @@ class Pv(AutomatedProperties): @staticmethod def _allocation_enabled(pv_uuid, pv_name, yes_no, allocation_options): # Make sure we have a dbus object representing it - dbo = cfg.om.get_object_by_uuid_lvm_id(pv_uuid, pv_name) - - if dbo: - rc, out, err = cmdhandler.pv_allocatable( - pv_name, yes_no, allocation_options) - if rc == 0: - cfg.load() - else: - raise dbus.exceptions.DBusException( - PV_INTERFACE, 'Exit code %s, stderr = %s' % (str(rc), err)) - else: - raise dbus.exceptions.DBusException( - PV_INTERFACE, - 'PV with uuid %s and name %s not present!' % - (pv_uuid, pv_name)) + Pv.validate_dbus_object(pv_uuid, pv_name) + rc, out, err = cmdhandler.pv_allocatable( + pv_name, yes_no, allocation_options) + Pv.handle_execute(rc, out, err) return '/' @dbus.service.method(