From: sbabic at denx.de Date: Sun, 19 Apr 2020 11:09:40 +0200 (CEST) Subject: [PATCH 2/4] dts: imx: Add fixed-link property to HSC and DDC (imx53) devices In-Reply-To: <20200226113703.10526-3-lukma@denx.de> Message-ID: <20200419090940.9A20181205@phobos.denx.de> List-Id: MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: u-boot@lists.denx.de > Those two boards are supposed to be run with a single u-boot binary. > There are notable differences though - HSC uses DSA switch (which > phy_id == 0x0) and DCC (DP83848C). > After the commit 3bf135b6c367 > ("drivers: net: phy: Ignore PHY ID 0 during PHY probing") the PHY devices > with phy_id == 0 are not created in U-Boot anymore. This caused regression > on HSC. > To fix this problem - the fec's 'fixed-link' node has been introduced and > the phy_id is not assessed anymore. This approach works on both boards. > Signed-off-by: Lukasz Majewski Applied to u-boot-imx, master, thanks ! Best regards, Stefano Babic -- ===================================================================== DENX Software Engineering GmbH, Managing Director: Wolfgang Denk HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: +49-8142-66989-53 Fax: +49-8142-66989-80 Email: sbabic at denx.de =====================================================================