From: sbabic at denx.de Date: Sun, 19 Apr 2020 11:09:59 +0200 (CEST) Subject: [PATCH v3 01/19] clk: imx: pllv3: add enable_bit In-Reply-To: <20200408151025.20549-2-giulio.benetti@benettiengineering.com> Message-ID: <20200419090959.961F981A27@phobos.denx.de> List-Id: MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: u-boot@lists.denx.de > pllv3 PLLs have powerdown/up bits but enable bits too. Specifically > "enable bit" enable the pll output, so when dis/enabling pll by > setting/clearing power_bit we must also set/clear enable_bit. > Signed-off-by: Giulio Benetti > Reviewed-by: Lukasz Majewski Applied to u-boot-imx, master, thanks ! Best regards, Stefano Babic -- ===================================================================== DENX Software Engineering GmbH, Managing Director: Wolfgang Denk HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: +49-8142-66989-53 Fax: +49-8142-66989-80 Email: sbabic at denx.de =====================================================================