From: Sean Anderson Date: Wed, 29 Jul 2020 05:56:35 -0400 Subject: [PATCH v2 6/7] riscv: Update Kendryte device tree for new CLINT driver In-Reply-To: <20200729095636.1077054-1-seanga2@gmail.com> References: <20200729095636.1077054-1-seanga2@gmail.com> Message-ID: <20200729095636.1077054-7-seanga2@gmail.com> List-Id: MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: u-boot@lists.denx.de AFAIK because the K210 clock driver does not come up until after relocation, the clint will always use the clock-frequency parameter. Ideally, it should update itself after relocation to take into account the actual CPU frequency. Signed-off-by: Sean Anderson --- Changes in v2: - New arch/riscv/dts/k210.dtsi | 9 ++++++--- 1 file changed, 6 insertions(+), 3 deletions(-) diff --git a/arch/riscv/dts/k210.dtsi b/arch/riscv/dts/k210.dtsi index 2546c7d4e0..2698a33a5c 100644 --- a/arch/riscv/dts/k210.dtsi +++ b/arch/riscv/dts/k210.dtsi @@ -17,6 +17,8 @@ compatible = "kendryte,k210"; aliases { + cpu0 = &cpu0; + cpu1 = &cpu1; dma0 = &dmac0; gpio0 = &gpio0; gpio1 = &gpio1_0; @@ -126,14 +128,15 @@ read-only; }; - clint0: interrupt-controller at 2000000 { + clint0: clint at 2000000 { #interrupt-cells = <1>; compatible = "kendryte,k210-clint", "riscv,clint0"; reg = <0x2000000 0xC000>; - interrupt-controller; interrupts-extended = <&cpu0_intc 3>, <&cpu0_intc 7>, <&cpu1_intc 3>, <&cpu1_intc 7>; - clocks = <&sysclk K210_CLK_CPU>; + clocks = <&sysclk K210_CLK_CLINT>; + /* sysclk is only available post-relocation */ + clock-frequency = <7800000>; }; plic0: interrupt-controller at C000000 { -- 2.27.0