From: Steven Scholz Date: Mon, 14 Apr 2003 15:16:50 +0200 Subject: [U-Boot-Users] "date reset" for MPC8xx Message-ID: <3E9AB4C2.6020500@imc-berlin.de> List-Id: MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: u-boot@lists.denx.de Hi there, I think would should realy reset the MPC8xx's internal RTC when calling "date reset" or "rtc_reset" instead of "nothing to do". Please find and consider the attached patch. Background: I have seen it several times, that the MPC8xx's internal RTC contains an invalid date, e.g. negative times (caused by no or low battery). That might result in dates before 1970-01-01 under Linux and that in turn confuses timeouts. I've seen that udhcpc (from busybox) hangs in such cases! For that reason u-boot should check for valid dates and do a rtc_reset() if nessesary. Thanks, Steven --------- CHANGELOG: * Patch by Steven Scholz, 14 Apr 2003: - reset_rtc() sets MPC8xx internal RTC back to 1970-01-01 -------------- next part -------------- An embedded and charset-unspecified text was scrubbed... Name: mpc8xx_rtc.patch Url: http://lists.denx.de/pipermail/u-boot/attachments/20030414/688eb3bf/attachment.txt