From: Christian Reis Subject: Re: General network slowness on SIS 530 with eepro100 Date: Fri, 16 Aug 2002 16:56:55 -0300 Sender: nfs-admin@lists.sourceforge.net Message-ID: <42426.6815455214$1029528006@news.gmane.org> References: <20020813212923.L2219@blackjesus.async.com.br> <200208150844.g7F8iQp19827@Port.imtp.ilyichevsk.odessa.ua> <20020815162155.L30462@blackjesus.async.com.br> <200208160824.g7G8Ogp24070@Port.imtp.ilyichevsk.odessa.ua> Mime-Version: 1.0 Content-Type: text/plain; charset=us-ascii Cc: eepro100@scyld.com, nfs@lists.sourceforge.net, linux-kernel@vger.kernel.org Return-path: Received: from calhau.terra.com.br ([200.176.3.20]) by usw-sf-list1.sourceforge.net with esmtp (Exim 3.31-VA-mm2 #1 (Debian)) id 17fnDo-0001It-00 for ; Fri, 16 Aug 2002 12:57:25 -0700 To: Denis Vlasenko In-Reply-To: <200208160824.g7G8Ogp24070@Port.imtp.ilyichevsk.odessa.ua>; from vda@port.imtp.ilyichevsk.odessa.ua on Fri, Aug 16, 2002 at 11:21:33AM -0200 Errors-To: nfs-admin@lists.sourceforge.net List-Help: List-Post: List-Subscribe: , List-Id: Discussion of NFS under Linux development, interoperability, and testing. List-Unsubscribe: , List-Archive: On Fri, Aug 16, 2002 at 11:21:33AM -0200, Denis Vlasenko wrote: > > > On 13 August 2002 22:29, Christian Reis wrote: > > > > On tri, which is the referred SIS530 box, as you can see, for most runs > > > > the CPU usage is just so much higher than minas, which has practically > > > > the same setup: K6-500, old PCI (no AGP) board, eepro100 card. I'm > > > > wondering if anybody has seen something like this before? > > Network card? Same type of network card in them them, swapped between them, no change. > Motherboard? :-) > BIOS? 8-) Yes, it has to be something in there. But they are not the same brand, and I've already updated the BIOS. > Compare BIOS/chipset setup (lspci -vvvxxx) Thanks for the suggestion. There are some items that differ between the outputs, as you can see below. One thing that is suggestive is that host bridge Control has I/O+ on problematic mobo, but I/O- on the normal one. I'm not sure what this affects, though. (BTW, I have triple checked, and there is no interrupt sharing going on). I've got to a point where I need to understand a bit more about how interrupts are handled by the hardware and kernel. I want to understand how it is possible for one network card in motherboard A to generate thousands of interrupts more than the same card in motherboard B for the same amount of net traffic. How does the kernel (or card?) schedule or postpone (batch?) the interrupts? Host bridge, Motherboard A (problematic): 00:00.0 Host bridge: Silicon Integrated Systems [SiS] 530 Host (rev 02) Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- Status: Cap+ 66Mhz- UDF- FastB2B- ParErr- DEVSEL=medium >TAbort- SERR- 00: 39 10 30 05 07 00 10 22 02 00 00 06 00 20 80 00 10: 00 00 00 e0 00 00 00 00 00 00 00 00 00 00 00 00 20: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 30: 00 00 00 00 c0 00 00 00 00 00 00 00 00 00 00 00 40: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 50: 90 98 e0 00 00 0d b2 00 50 00 00 00 00 18 00 00 60: 26 06 06 67 00 00 00 00 c0 00 00 00 00 00 00 00 70: cc 80 00 00 88 88 88 00 00 00 00 00 00 00 00 00 80: 00 00 80 03 60 00 03 44 00 10 7b 00 48 00 00 00 90: 00 00 00 00 40 00 00 01 00 00 00 00 00 00 00 00 a0: 40 40 80 00 00 00 00 00 00 00 00 00 00 00 00 00 b0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 c0: 02 00 20 00 03 02 00 1f 00 00 00 00 00 00 00 00 d0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 e0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 f0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Host bridge, Motherboard B (normal): 00:00.0 Host bridge: Acer Laboratories Inc. [ALi] M1541 (rev 04) Subsystem: Acer Laboratories Inc. [ALi] ALI M1541 Aladdin V/V+ AGP System Controller Control: I/O- Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- Status: Cap+ 66Mhz- UDF- FastB2B- ParErr- DEVSEL=slow >TAbort- SERR- 00: b9 10 41 15 06 00 10 24 04 00 00 06 00 40 00 00 10: 00 00 00 d0 00 00 00 00 00 00 00 00 00 00 00 00 20: 00 00 00 00 00 00 00 00 00 00 00 00 b9 10 41 15 30: 00 00 00 00 b0 00 00 00 00 00 00 00 00 00 00 00 40: 13 04 81 75 00 01 00 06 09 ef a0 5c 00 00 ff ff 50: 00 f0 00 cc 00 05 07 ff 00 00 00 00 00 00 08 00 60: 00 00 00 00 00 00 00 00 7f b0 ff b0 ff 00 ff 00 70: 00 30 46 02 00 00 00 00 00 00 00 00 00 00 00 00 80: 00 00 00 00 0f c8 07 1e ea 20 20 00 00 4b 42 32 90: 20 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 a0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 b0: 02 00 10 00 03 02 00 1c 00 00 00 00 0a 00 00 00 c0: 90 00 fd df 00 00 00 00 bf 4a 00 00 00 00 00 10 d0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 e0: 01 00 01 00 00 00 00 00 00 00 00 00 38 11 0c 29 f0: 00 00 00 08 00 90 95 03 00 00 00 00 00 00 00 00 Ethernet controller, Motherboard A (problematic): 00:0b.0 Ethernet controller: Intel Corp. 82557 [Ethernet Pro 100] (rev 08) Subsystem: Intel Corp. EtherExpress PRO/100+ Management Adapter Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV+ VGASnoop- ParErr- Stepping- SERR- FastB2B- Status: Cap+ 66Mhz- UDF- FastB2B+ ParErr- DEVSEL=medium >TAbort- SERR- [disabled] [size=1M] Capabilities: [dc] Power Management version 2 Flags: PMEClk- DSI+ D1+ D2+ AuxCurrent=0mA PME(D0+,D1+,D2+,D3hot+,D3cold-) Status: D0 PME-Enable- DSel=0 DScale=2 PME- 00: 86 80 29 12 17 00 90 02 08 00 00 02 08 20 00 00 10: 00 00 80 c7 01 d8 00 00 00 00 00 c7 00 00 00 00 20: 00 00 00 00 00 00 00 00 00 00 00 00 86 80 0c 00 30: 00 00 00 00 dc 00 00 00 00 00 00 00 0b 01 08 38 40: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 50: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 60: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 70: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 80: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 90: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 a0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 b0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 c0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 d0: 00 00 00 00 00 00 00 00 00 00 00 00 01 00 22 7e e0: 00 40 00 3a 00 00 00 00 00 00 00 00 00 00 00 00 f0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Ethernet controller, Motherboard B (normal): 00:0b.0 Ethernet controller: Intel Corp. 82557 [Ethernet Pro 100] (rev 08) Subsystem: Intel Corp. EtherExpress PRO/100+ Management Adapter Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV+ VGASnoop- ParErr- Stepping- SERR- FastB2B- Status: Cap+ 66Mhz- UDF- FastB2B+ ParErr- DEVSEL=medium >TAbort- SERR- [disabled] [size=1M] Capabilities: [dc] Power Management version 2 Flags: PMEClk- DSI+ D1+ D2+ AuxCurrent=0mA PME(D0+,D1+,D2+,D3hot+,D3cold+) Status: D0 PME-Enable- DSel=0 DScale=2 PME- 00: 86 80 29 12 17 00 90 02 08 00 00 02 08 20 00 00 10: 00 00 80 de 01 a4 00 00 00 00 00 de 00 00 00 00 20: 00 00 00 00 00 00 00 00 00 00 00 00 86 80 0c 00 30: 00 00 00 00 dc 00 00 00 00 00 00 00 0a 01 08 38 40: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 50: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 60: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 70: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 80: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 90: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 a0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 b0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 c0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 d0: 00 00 00 00 00 00 00 00 00 00 00 00 01 00 22 fe e0: 00 40 00 3a 00 00 00 00 00 00 00 00 00 00 00 00 f0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Take care, -- Christian Reis, Senior Engineer, Async Open Source, Brazil. http://async.com.br/~kiko/ | [+55 16] 261 2331 | NMFL ------------------------------------------------------- This sf.net email is sponsored by: OSDN - Tired of that same old cell phone? Get a new here for FREE! https://www.inphonic.com/r.asp?r=sourceforge1&refcode1=vs3390 _______________________________________________ NFS maillist - NFS@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/nfs