From: Stefan Richter Date: Sat, 11 Aug 2007 15:48:41 +0000 Subject: Re: [lm-sensors] 2.6.23-rc1 regression: hwmon/w83627ehf: wrong fan Message-Id: <46BDDA59.5070302@s5r6.in-berlin.de> List-Id: References: <46B5B290.4040907@s5r6.in-berlin.de> <20070805162141.GI6221@jupiter.solarsys.private> <46B6053E.2050708@s5r6.in-berlin.de> <20070810230831.59cbc50f@hyperion.delvare> <46BCE6D0.7060300@s5r6.in-berlin.de> <20070811135705.0d0688d7@hyperion.delvare> <46BDD8B3.8070708@s5r6.in-berlin.de> In-Reply-To: <46BDD8B3.8070708@s5r6.in-berlin.de> MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: Jean Delvare Cc: "Mark M. Hoffman" , lm-sensors@lm-sensors.org, linux-kernel@vger.kernel.org > Jean Delvare wrote: >> So my theory is that something else (BIOS, ACPI?) (ksensors?) >> is changing the bank, >> probably to read temperature values which are in banks 1 and 2, causing >> the w83627ehf to get a wrong value for the VBAT register. If I am >> right, then the attached patch should help. Please give it a try and >> report. This patch fixes the issue. (I didn't reboot, only reloaded the drivers after patching.) Thanks for your help and advice. -- Stefan Richter -===-=-== =--- -=-= http://arcgraph.de/sr/ _______________________________________________ lm-sensors mailing list lm-sensors@lm-sensors.org http://lists.lm-sensors.org/mailman/listinfo/lm-sensors