From: Iordan Iordanov Subject: failing a drive while RAID5 is initializing Date: Wed, 23 Feb 2011 11:20:34 -0500 Message-ID: <4D6533D2.3020600@cdf.toronto.edu> Mime-Version: 1.0 Content-Type: text/plain; charset=ISO-8859-1; format=flowed Content-Transfer-Encoding: 7bit Return-path: Sender: linux-raid-owner@vger.kernel.org To: linux-raid@vger.kernel.org List-Id: linux-raid.ids Hi guys, I just wanted to make sure that the behaviour I observed is as expected. With kernel 2.6.35.11, under Debian Lenny, I created a RAID5 array with 5 drives, partitioned it, formatted a partition with ext3 and mounted it. Then, I put some load onto the filesystem with: dd if=/dev/urandom of=/mnt/testfile The array started initializing. At that point, I needed to fail and replace a drive for some unrelated testing, so I did that with: mdadm /dev/md0 -f /dev/sdc The result was a broken filesystem which was remounted read-only, and a bunch of errors in dmesg. Theoretically, one would imagine that failing a drive on a RAID5 even during initialization should render the array without redundancy but workable. Am I wrong? Is there something special about the initialization stage of RAID5 that makes drive failure fatal during the initialization? If not, then I have a bug to report and I'll try to reproduce it for you. If initialisation is special, does that mean that when creating RAID5, it is advisable to *wait* until the array has fully initialized before using it, otherwise one risks losing any data that was put onto the array during the initialization phase if a drive fails at that point? Many thanks for any input, Iordan Iordanov