From: Guenter Roeck Date: Fri, 23 Jan 2015 15:55:45 +0000 Subject: Re: [lm-sensors] [PATCH] hwmon: (jc42) Allow negative hysteresis temperatures Message-Id: <54C26F01.1020100@roeck-us.net> List-Id: References: <20150123102703.4ff3ce85@endymion.delvare> In-Reply-To: <20150123102703.4ff3ce85@endymion.delvare> MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: lm-sensors@vger.kernel.org On 01/23/2015 01:27 AM, Jean Delvare wrote: > The driver supports negative high and critical limits, it can return > negative hysteresis values, so there is no good reason to not let the > user write negative hysteresis values. > > Signed-off-by: Jean Delvare > Cc: Guenter Roeck > --- Hi Jean, thanks for looking into this. Applied. Thanks, Guenter _______________________________________________ lm-sensors mailing list lm-sensors@lm-sensors.org http://lists.lm-sensors.org/mailman/listinfo/lm-sensors