From: Luca Tettamanti Date: Tue, 21 Jul 2009 10:57:57 +0000 Subject: Re: [lm-sensors] [PATCH] asus_atk0110: fix limit readings Message-Id: <68676e00907210357w4aa962d6o32e149eb33aa5012@mail.gmail.com> List-Id: References: <20090721092742.GA11055@nb-core2.darkstar.lan> In-Reply-To: <20090721092742.GA11055@nb-core2.darkstar.lan> MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: lm-sensors@vger.kernel.org On Tue, Jul 21, 2009 at 12:36 PM, Jean Delvare wrote: > Hi Luca, > > On Tue, 21 Jul 2009 11:27:42 +0200, Luca Tettamanti wrote: >> On newer Asus boards the "upper" limit of a sensor is encoded as delta from the >> "lower" limit. Fix the driver to correctly handle this case. >> Note that the bug is purely cosmetic. > > I don't see how it would be only cosmetic, if the driver was reporting > wrong upper limits before. I mean that it didn't affect the correct operation of the thresholds (at least in the firmware). Luca _______________________________________________ lm-sensors mailing list lm-sensors@lm-sensors.org http://lists.lm-sensors.org/mailman/listinfo/lm-sensors