Received: from eggs.gnu.org ([2001:4830:134:3::10]:49559) by lists.gnu.org with esmtp (Exim 4.71) (envelope-from ) id 1XPpRj-0001bk-VM for qemu-devel@nongnu.org; Fri, 05 Sep 2014 05:04:49 -0400 Received: from Debian-exim by eggs.gnu.org with spam-scanned (Exim 4.71) (envelope-from ) id 1XPpRf-0005CF-06 for qemu-devel@nongnu.org; Fri, 05 Sep 2014 05:04:43 -0400 From: Markus Armbruster References: <1409115651-3612-1-git-send-email-john.liuli@huawei.com> <87iolefn36.fsf@blackfin.pond.sub.org> <53FD8B7D.7030301@huawei.com> <54091432.4050904@huawei.com> Date: Fri, 05 Sep 2014 11:04:26 +0200 In-Reply-To: <54091432.4050904@huawei.com> (Li Liu's message of "Fri, 5 Sep 2014 09:38:58 +0800") Message-ID: <87bnqujv51.fsf@blackfin.pond.sub.org> MIME-Version: 1.0 Content-Type: text/plain Subject: Re: [Qemu-devel] [PATCH] qemu-char: fix terminal crash when using "-monitor stdio -nographic" List-Id: List-Unsubscribe: , List-Archive: List-Post: List-Help: List-Subscribe: , To: Li Liu Cc: qemu-trivial@nongnu.org, qemu-devel@nongnu.org, Gerd Hoffmann Li Liu writes: > Ping, any more comments? Thanks. I'd like to hear Gerd's opinion (cc'ed). > On 2014/8/27 15:40, Li Liu wrote: >> >> >> On 2014/8/27 14:44, Markus Armbruster wrote: >>> "john.liuli" writes: >>> >>>> From: Li Liu >>>> >>>> Eeay to reproduce, just try "qemu -monitor stdio -nographic" >>>> and type "quit", then the terminal will be crashed. >>>> >>>> There are two pathes try to call tcgetattr of stdio in vl.c: >>>> >>>> 1) Monitor_parse(optarg, "readline"); >>>> ..... >>>> qemu_opts_foreach(qemu_find_opts("chardev"), >>>> chardev_init_func, NULL, 1) != 0) >>>> >>>> 2) if (default_serial) >>>> add_device_config(DEV_SERIAL, "stdio"); >>>> .... >>>> if (foreach_device_config(DEV_SERIAL, serial_parse) < 0) >>>> >>>> Both of them will trigger qemu_chr_open_stdio which will disable >>>> ECHO attributes. First one has updated the attributes of stdio >>>> by calling qemu_chr_fe_set_echo(chr, false). And the tty >>>> attributes has been saved in oldtty. Then the second path will >>>> redo such actions, and the oldtty is overlapped. So till "quit", >>>> term_exit can't recove the correct attributes. >>>> >>>> Signed-off-by: Li Liu >>> >>> Yes, failure to restore tty settings is a bug. >>> >>> But is having multiple character devices use the same terminal valid? >> >> I'm not sure. But I have found such comments in vl.c >> "According to documentation and historically, -nographic redirects >> serial port, parallel port and monitor to stdio" >> >> Best regards >> Li. >> >>> If no, can we catch and reject the attempt? >>> >>> [...]