From: "Erik Welander" Subject: Verification Request for Filter Divider calculation; ES18XX.c Date: Wed, 12 Mar 2003 18:25:09 +0100 Sender: alsa-devel-admin@lists.sourceforge.net Message-ID: Mime-Version: 1.0 Content-Type: text/plain; format=flowed Return-path: Errors-To: alsa-devel-admin@lists.sourceforge.net List-Help: List-Post: List-Subscribe: , List-Unsubscribe: , List-Archive: To: alsa-devel@lists.sourceforge.net List-Id: alsa-devel@alsa-project.org I am looking into the ES18XX driver for my ES1878. Now, I get static when using only the second DMA channel, as dma1=5, dma2=5, and no other errors. (The firstDMA channel does not work at all…) My investigation points to that there may be problems in the sample rate/filter divider calculations. Could any knowledgeable person verify if this calculation incorrect or not: /* set filter register */ div0 = 256 - 7160000*20/(8*82*runtime->rate); Here is the text outlining the procedure from the Datasheet for ES1878: This register controls the low-pass frequency of the switchcapacitor filters inside the ES1878. Generally, the filter rolloff should be positioned at 80% - 90% of the Sample_Rate/ 2 frequency. The ratio of the roll-off frequency to the filter clock frequency is 1:82. In other words, first determine the desired roll-off frequency by taking 80% of the Sample_Rate divided by 2, then multiply by 82 to find the desired Filter Clock frequency. Use the formula below to determine the closest divider: Filter_Clock_Frequency = 7.16 MHz / (256-Filter_Divider_Register) Regards From Erik _________________________________________________________________ Tired of spam? Get advanced junk mail protection with MSN 8. http://join.msn.com/?page=features/junkmail ------------------------------------------------------- This SF.net email is sponsored by:Crypto Challenge is now open! Get cracking and register here for some mind boggling fun and the chance of winning an Apple iPod: http://ads.sourceforge.net/cgi-bin/redirect.pl?thaw0031en