From: HU Chunlin Date: Tue, 23 Mar 2004 01:59:54 +0000 Subject: [U-Boot-Users] MPC8280 bus_clk Message-ID: List-Id: MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: u-boot@lists.denx.de Thank you for the quick reply. So for at least 8266 CPU running PCI agent mode, the CONFIG_8260_CLKIN definition must be set to 2 x PCI_CLK, and the bus_clk must be calculated as gd->bus_clk = gd->vco_out / (busdf + 1)? If so, I think there must be a patch for it. Regards, HU Chunlin >From: "Rune Torgersen" >To: "HU Chunlin" >Subject: RE: [U-Boot-Users] MPC8280 bus_clk >Date: Mon, 22 Mar 2004 10:40:31 -0600 > >That is a problem for at least eht 8266 CPU when set in PCI agent mode, >because the clockiin is then 2x the PCI clock, and is not the bus clock >(which is multiplied up from that) > > > I got some information from the Technical Support Engineering > > Team of Motorola that the statement BUS_CLK == CLKIN applies > > to local bus mode only. _________________________________________________________________ ?????????????? MSN Messenger: http://messenger.msn.com/cn