From: Keir Fraser Subject: Re: s_time going backwards on same processor? Date: Sat, 26 Jul 2008 16:14:24 +0100 Message-ID: References: <20080726085034640.00000008444@djm-pc> Mime-Version: 1.0 Content-Type: text/plain; charset="ISO-2022-JP" Content-Transfer-Encoding: 7bit Return-path: In-Reply-To: <20080726085034640.00000008444@djm-pc> List-Unsubscribe: , List-Post: List-Help: List-Subscribe: , Sender: xen-devel-bounces@lists.xensource.com Errors-To: xen-devel-bounces@lists.xensource.com To: "dan.magenheimer@oracle.com" , "Tian, Kevin" , "Xen-Devel (E-mail)" Cc: Dave Winchell List-Id: xen-devel@lists.xenproject.org Which clocksource was this with? It would be worth saving the previous tsc and struct cpu_time values so you can print those out when you see s_time goes backwards. It'll make it much easier to see what actually went 'backwards' -- also we could run through the 'prev' and 'now' s_time calculation arithmetic manually to see if any of the arithmetic is at fault. -- Keir On 26/7/08 15:50, "Dan Magenheimer" wrote: > Thanks Kevin for catching that. I fixed it using spin_lock_irqsave > and spin_unlock_irqrestore and have already seen stime going > backwards... I haven't retested all the clocksources and smp. > but it doesn't appear that the incorrect enablement of > interrupts was the problem. > > It's interesting that the problem occurs even with one processor. > Hopefully that will make it easier to debug. > > Updated debug patch attached. > > Thanks, > Dan > >> -----Original Message----- >> From: Keir Fraser [mailto:keir.fraser@eu.citrix.com] >> Sent: Saturday, July 26, 2008 12:51 AM >> To: Tian, Kevin; dan.magenheimer@oracle.com; Xen-Devel (E-mail) >> Cc: Dave Winchell >> Subject: Re: s_time going backwards on same processor? >> >> >> The code should be using spin_lock_irqsave/spin_unlock_irqrestore. >> >> As it is it's incorrect and could cause odd behaviour. I >> don't know whether >> that would extend to seeing time goes backwards as often as >> Dan reports, but >> obviously the test has to be re-run. >> >> -- Keir >> >> On 26/7/08 03:23, "Tian, Kevin" wrote: >> >>> In a quick glimpse, your measure_stime_skew has interrupt >>> enabled absolutely at exit, instead of restoring previous >>> setting. Would it be a trouble-maker? I have no latest code >>> at hand, but at least for what I can check: >>> >>> in local_time_calibration: >>> >>> local_irq_disable(); >>> curr_master_stime = read_platform_stime(); >>> curr_local_stime = get_s_time(); >>> rdtscll(curr_tsc); >>> local_irq_enable(); >>> >>> with your patch, interrupt is enabled after get_s_time, which >>> then may have curr_tsc read out from a different time point... >>> >>> Thanks, >>> Kevin >>> >>>> From: Dan Magenheimer [mailto:dan.magenheimer@oracle.com] >>>> Sent: 2008年7月26日 9:47 >>>> >>>> OK, I am definitely recording stime going backwards >>>> observed with the attached patch. I have recorded dozens >>>> over a few hours. It appears to have no >>>> obvious pattern between reports, but one thing >>>> is consistent: In all cases, t->tsc_scale.shift >>>> is -1. I'll try to run some more tests over the >>>> weekend (e.g. with different clocksources... this >>>> is with clocksource=hpet), but thought I'd report >>>> what I have seen. I'm running on a dual-core single >>>> socket ("Conroe"). >>>> >>>> Dan >>>> >>>> P.S. If you try the patch, ensure you set >>>> the boot parameter "measurestime". >>>> >>>>> -----Original Message----- >>>>> From: Keir Fraser [mailto:keir.fraser@eu.citrix.com] >>>>> Sent: Wednesday, July 23, 2008 1:06 AM >>>>> To: dan.magenheimer@oracle.com; Xen-Devel (E-mail) >>>>> Cc: Dave Winchell >>>>> Subject: Re: s_time going backwards on same processor? >>>>> >>>>> >>>>> On 22/7/08 22:58, "Dan Magenheimer" >>>>> wrote: >>>>> >>>>>> I *do* know that get_s_time() on different processors >>>>>> can have this behavior and I know it is possible for >>>>>> hvm_get_guest_time() to go backwards (timer_mode=0), >>>>>> but I thought s_time was monotonically non-decreasing >>>>>> on any given processor and that read_platform_stime() >>>>>> is also monotonically non-decreasing. >>>>>> >>>>>> Does dom0 maybe have direct hardware access to the hardware >>>>>> platform timer that xen system time is dependent on? >>>>> >>>>> No matter what happens to the underlying platform timer, >> it should be >>>>> impossible for Xen system time to go backwards on any given >>>>> processor. The >>>>> calibration function never sets the TSC and system timestamps >>>>> for the next >>>>> time record any earlier than current TSC value and current >>>>> computed system >>>>> time value. Hence it should be impossible for system time to >>>>> be computed as >>>>> earlier than that time record. >>>>> >>>>> -- Keir >>>>> >>>>> >>>>> >>>> >> >> >>