From: Paul Davis Subject: Re: Hammerfall configuration Date: Thu, 19 Dec 2002 12:28:17 -0500 Sender: alsa-devel-admin@lists.sourceforge.net Message-ID: References: <3E01FA02.D0B4CD44@earthlink.net> Return-path: In-reply-to: Your message of "Thu, 19 Dec 2002 10:55:30 CST." <3E01FA02.D0B4CD44@earthlink.net> Errors-To: alsa-devel-admin@lists.sourceforge.net List-Help: List-Post: List-Subscribe: , List-Unsubscribe: , List-Archive: To: patrick reardon Cc: alsa-devel@lists.sourceforge.net List-Id: alsa-devel@alsa-project.org >by hand, changing the 'Sync Mode' value from AutoSync to Master >(should these values be in quotes?), ran "alsactl store hammerfall", >unloaded then reloaded the alsa m odules, then ran "alsactl restore >hammerfall. ("hammerfall" is the card's id.) but asound .state >still indicates Sync Mode is set to AutoSync. "vi >/proc/asound/hammerfall/rme 9652" reads you got the process wrong. 1) alsactl store hammerfall 2) edit file 3) alsactl restore hammerfall no driver unload/load is needed. each time you reload the module without the 3rd step, you get back to the driver's own default settings. >i'm also curious if the "IEC958 sample rate: error flag set" is normal and if >not, what to >look at to fix it. asound.state says it means you have no s/pdif input. --p ------------------------------------------------------- This SF.NET email is sponsored by: Geek Gift Procrastinating? Get the perfect geek gift now! Before the Holidays pass you by. T H I N K G E E K . C O M http://www.thinkgeek.com/sf/