References: <20210512125544.9536-1-mreitz@redhat.com> <20210512125544.9536-2-mreitz@redhat.com> <20210526181324.GA1222711@redhat.com> <20210526185017.GB1225492@horse> From: Max Reitz Message-ID: Date: Thu, 27 May 2021 17:00:31 +0200 MIME-Version: 1.0 In-Reply-To: <20210526185017.GB1225492@horse> Content-Type: text/plain; charset="utf-8"; format="flowed" Content-Language: en-US Content-Transfer-Encoding: 8bit Subject: Re: [Virtio-fs] [PATCH 1/3] virtiofsd: Find original inode ID of mount points List-Id: Development discussions about virtio-fs List-Unsubscribe: , List-Archive: List-Post: List-Help: List-Subscribe: , To: Vivek Goyal Cc: virtio-fs-list , qemu-devel@nongnu.org On 26.05.21 20:50, Vivek Goyal wrote: > On Wed, May 26, 2021 at 02:13:24PM -0400, Vivek Goyal wrote: >> On Wed, May 12, 2021 at 02:55:42PM +0200, Max Reitz wrote: >>> Mount point directories represent two inodes: On one hand, they are a >>> normal directory on their parent filesystem. On the other, they are the >>> root node of the filesystem mounted there. Thus, they have two inode >>> IDs. >>> >>> Right now, we only report the latter inode ID (i.e. the inode ID of the >>> mounted filesystem's root node). This is fine once the guest has >>> auto-mounted a submount there (so this inode ID goes with a device ID >>> that is distinct from the parent filesystem), but before the auto-mount, >>> they have the device ID of the parent and the inode ID for the submount. >>> This is problematic because this is likely exactly the same >>> st_dev/st_ino combination as the parent filesystem's root node. This >>> leads to problems for example with `find`, which will thus complain >>> about a filesystem loop if it has visited the parent filesystem's root >>> node before, and then refuse to descend into the submount. >>> >>> There is a way to find the mount directory's original inode ID, and that >>> is to readdir(3) the parent directory, look for the mount directory, and >>> read the dirent.d_ino field. Using this, we can let lookup and >>> readdirplus return that original inode ID, which the guest will thus >>> show until the submount is auto-mounted. >> >>> (Then, it will invoke getattr >>> and that stat(2) call will return the inode ID for the submount.) >> >> Hi Max, >> >> How are we sure that GETATTR() will always be called and that will >> allow us to return inode number in mounted filesystem (instead of >> parent filesystem). I thought GETATTR will be called only if cached >> attrs have expired. (1 second default for cache=auto). Otherwise >> stat() will fill inode->i_no from cache and return. And I am afraid >> that in that case we will return inode number from parent fs, >> instead of mounted fs. >> >> Say following sequence of events happens pretty fast one after the >> other. Say /mnt/virtiofs/foo is a mount point in server but client >> has not created submount yet. >> >> A. stat(/mnt/virtiofs/foo, AT_NO_AUTOMOUNT) >> -> This should get inode number in parent filesystem on host and >> store in guest inode->i_no and return to user space. Say inode >> in guest is called a_ino. >> B. stat(/mnt/virtiofs/foo) >> -> This should create submount and create new inode (say b_ino), using >> properties from a_ino. IOW, this should copy a_ino->i_no to >> b_ino->b_ino given current code, IIUC. >> >> -> Assume timeout has not happened and cached attrs have not expired. >> >> -> And now b_ino->i_no (or ->orig_ino) will be returned to user space. Well, I mean, this sounds easy enough to test. For example, this passes for me: count=1000 root_st_ino=128 tag=host mountpoint=/mnt submount_path=submount for i in $(seq $count) do mount -t virtiofs $tag $mountpoint || break if [ $(stat -c '%i' $mountpoint/$submount_path) -eq $root_st_ino ] then echo 'fail 0' break fi ls $mountpoint/$submount_path > /dev/null if [ $(stat -c '%i' $mountpoint/$submount_path) -ne $root_st_ino ] then echo 'fail 1' break fi umount $mountpoint || break done if [ $i -ne $count ] then echo 'Something failed' else echo 'OK' fi >> Am I missing something. Do we need to always expire inode attrs when >> we create submount so that client is forced to issue GETATTR. > > Looks like while initialzing b_ino, we are setting attr_valid=0, which > should set fi->i_time=0 and force issuing GETATTR later. > > fuse_fill_super_submount() > root = fuse_iget(sb, parent_fi->nodeid, 0, &root_attr, 0, 0); > ^ > fuse_iget(attr_valid=0) > fuse_change_attributes(attr_valid=0) > fuse_change_attributes_common(attr_valid=0) > fi->i_time = attr_valid; > > So may be this will force GETATTR and fetch new inode id when second > stat() is called. i_time is at least what fuse_update_get_attr() uses to decide whether to invoke GETATTR or not – although AT_STATX_DONT_SYNC can override that, but I don’t think that’s a problem. If i_time is 0, that function will always invoke GETATTR (unless AT_STATX_DONT_SYNC). So I think it works in practice. When the inode ID is looked up through some stat-y function, this should go through fuse_update_get_attr(), which will fetch the st_ino on the submount. There is still i_ino, though... To be absolutely certain, we could invoke fuse_update_attributes() in fuse_fill_super_submount(), but then again, fuse_fill_super_common() doesn’t do that either for its root node. It just initializes i_ino to FUSE_ROOT_ID, i.e. 1. Max