Message-ID: Date: Fri, 16 Dec 2005 14:53:02 +0200 From: Dmitry Adamushko MIME-Version: 1.0 Content-Type: multipart/alternative; boundary="----=_Part_6628_12524804.1134737582697" Subject: [Xenomai-help] [testsuite/latency] intervals are much > than 1 second List-Id: Help regarding installation and common use of Xenomai List-Unsubscribe: , List-Archive: List-Post: List-Help: List-Subscribe: , To: xenomai@xenomai.org ------=_Part_6628_12524804.1134737582697 Content-Type: text/plain; charset=ISO-8859-1 Content-Transfer-Encoding: quoted-printable Content-Disposition: inline Hello all, I have been out of xeno-scope for a while so maybe I successufy missed something important that might be the explanation of a problem described below. The problem is as follows: x86-ipipe-1.0.10 && xenomai-2.1 (CVS: ~ November, 21) testsuite/letency is used as it is by defaulty (nsamples =3D 1 billion (1 second) / sample (e.g.100000 us)) I am used to getting data with ~1-second-interval on the screen when "latency" is running and so expected to observe the same behaviour now. Nevertheless, the interval (with all parameters by default) is ~ 4 seconds, and it gets up to 16-17 seconds when -p 1000 (sampling period =3D=3D 1 ms.)= is used. e.g. it took 1 minute and 30 seconds to get 21 lines of statistics on the screen (-p 100) but should have been ~22-23 seconds. And the latency thread really reported the presence of collected data 21 times (through rt_sem_v()) . So have I missed something important? any ideas are wellcome. -- Best regards, Dmitry Adamushko ------=_Part_6628_12524804.1134737582697 Content-Type: text/html; charset=ISO-8859-1 Content-Transfer-Encoding: quoted-printable Content-Disposition: inline
Hello all,

I have been out of xeno-scope for a while so maybe I successufy missed some= thing important
that might be the explanation of a problem described below.

The problem is as follows:

x86-ipipe-1.0.10 && xenomai-2.1 (CVS: ~ November, 21)

testsuite/letency is used as it is by defaulty (nsamples =3D 1 billion (1 s= econd) / sample (e.g.100000 us))

I am used to getting data with ~1-second-interval on the screen when "latency" is running and so expected to observe the same behaviou= r now.

Nevertheless, the interval (with all parameters by default) is ~ 4 seconds, and it gets up to 16-17 seconds when -p 1000 (sampling period =3D=3D 1 ms.) is used.

e.g. it took 1 minute and 30 seconds to get 21 lines of statistics on the s= creen (-p 100) but should have been ~22-23 seconds.

And the latency thread really reported the presence of collected data 21 ti= mes (through rt_sem_v()) .

So have I missed something important? any ideas are wellcome.

--
Best regards,
Dmitry Adamushko ------=_Part_6628_12524804.1134737582697--