From: Jaehoon Chung Date: Fri, 29 Jan 2021 07:00:48 +0900 Subject: [RESEND PATCH v1 1/1] mmc: fix response timeout after switch command In-Reply-To: <6630b904-1ec5-63b4-7301-be11ce0bc151@posteo.net> References: <20210123123741.3224-1-stefan_b@posteo.net> <20210123123741.3224-2-stefan_b@posteo.net> <6630b904-1ec5-63b4-7301-be11ce0bc151@posteo.net> Message-ID: List-Id: MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: u-boot@lists.denx.de Hi Stefan, On 1/29/21 4:23 AM, Stefan Bosch wrote: > Hi, > > On 27.01.21 00:38, Jaehoon Chung wrote: >> Hi, >> >> On 1/23/21 9:37 PM, Stefan Bosch wrote: >>> After issuing the switch command: Wait until 'current state' of the card >>> status becomes 'tran'. This prevents from response timeout at the next >>> command because of 'current state' = 'data'.> >>> Signed-off-by: Stefan Bosch >>> --- >>> >>> ? drivers/mmc/mmc.c | 3 ++- >>> ? include/mmc.h???? | 1 + >>> ? 2 files changed, 3 insertions(+), 1 deletion(-) >>> >>> diff --git a/drivers/mmc/mmc.c b/drivers/mmc/mmc.c >>> index a47700e313..8ccd2058a9 100644 >>> --- a/drivers/mmc/mmc.c >>> +++ b/drivers/mmc/mmc.c >>> @@ -823,7 +823,8 @@ static int __mmc_switch(struct mmc *mmc, u8 set, u8 index, u8 value, >>> ?????????????????? value); >>> ????????????? return -EIO; >>> ????????? } >>> -??????? if (!ret && (status & MMC_STATUS_RDY_FOR_DATA)) >>> +??????? if (!ret && (status & MMC_STATUS_RDY_FOR_DATA) && >>> +??????????? (status & MMC_STATUS_CURR_STATE) == MMC_STATE_TRANS) >> >> AFAIK, MMC_STATUS_RDY_FOR_DATA bit means the signaling about "buffer is empty". >> Even though its bit was set, does it need to check TRANS state? >> >> Best Regards, >> Jaehoon Chung >> > > After issuing command 'MMC_CMD_SWITCH' = CMD6 the state transits to 'DATA'. But in DATA state it is not possible to issue a (new) CMD except CMD12 (operation complete) and CMD7 (select/deselect card). See appropriate State Diagram, e.g. "Figure 4-3: SD Memory Card State Diagram (data transfer mode)" in "SD Specifications Part 1 - Physical Layer - Simplified Specification - Version 2.00". Status 'Ready For Data' is in my opinion only relevant for CMD12 and CMD7. Thanks for explanation. I have checked Spec about SD and eMMC. It makes sense. Reviewed-by: Jaehoon Chung Best Regards, Jaehoon Chung > > Regards > Stefan Bosch > >>> ????????????? return 0; >>> ????????? udelay(100); >>> ????? } while (get_timer(start) < timeout_ms); >>> diff --git a/include/mmc.h b/include/mmc.h >>> index 1d377e0281..18402494c6 100644 >>> --- a/include/mmc.h >>> +++ b/include/mmc.h >>> @@ -178,6 +178,7 @@ static inline bool mmc_is_tuning_cmd(uint cmdidx) >>> ? #define MMC_STATUS_ERROR??? (1 << 19) >>> ? ? #define MMC_STATE_PRG??????? (7 << 9) >>> +#define MMC_STATE_TRANS??????? (4 << 9) >>> ? ? #define MMC_VDD_165_195??????? 0x00000080??? /* VDD voltage 1.65 - 1.95 */ >>> ? #define MMC_VDD_20_21??????? 0x00000100??? /* VDD voltage 2.0 ~ 2.1 */ >>> >> >