From: "Derek Engelhaupt" <[email protected]>
Subject: RE: [parisc-linux] Disk problems

Quoted 1 line

I had a 712/100 at work that we (ok I) modified to take 2 internal disks

and it ran

Quoted 1 line

well even though it got extremely hot inside since the 712 wasn't designed

for

Quoted 1 line

efficiant cooling. I was using 2 C2490s in it, but quit doing so because

of the

Quoted 1 line

heat and also moved one of the disks to an external chassis. The mod was

done by

Quoted 1 line

using the internal SCSI cable of a 715 and removing the floppy drive. Not

a

Quoted 1 line

recommended solution, but the 712 power supply seemed to be able to keep

up.

This is definitively NOT recommended. I tried this in a 712/60 and almost lost one of the disks. Powerer supply wasn't strong enough to spinn up 2 disks, and a varistor blow up.

Greetings, Yves...

#1 lore raw

when i'm doing the disk cloning i'm actually using 2 workstations to power the drives separately & a scsi cable long enough to reach both disks, so i dont think its a spin up issue

James S

Quoted 9 lines
Quoted 1 line

recommended solution, but the 712 power supply seemed to be able to keep

up.

This is definitively NOT recommended. I tried this in a 712/60 and almost lost one of the disks. Powerer supply wasn't strong enough to spinn up 2 disks, and a varistor blow up.

Greetings, Yves...

#2 lore raw
Quoted 3 lines

when i'm doing the disk cloning i'm actually using 2 workstations to power the drives separately & a scsi cable long enough to reach both disks, so i dont think its a spin up issue

On old drives, you can hear them spin up. When they reach operational speed, there is usually a click when the heads are released followed by some head motion (thermal calibration). If you don't hear the click, then the drive is probably not spinning up. Seagates have a jumper that controls whether the drive requires a scsi command to start or not. The default jumper setting is to start at power on.

Dave

Signature · 2 lines
J. David Anglin                                  [email protected]
National Research Council of Canada              (613) 990-0752 (FAX: 952-6605)