Skip to contentSkip to conversation

raid-1 with ide-scsi emulation and mkswap failure

DISCUSSION Eric Wood 3 participants 4 messages Apr 15, 2004 – Apr 16, 2004 MD RAID

lore
Share & tools
lore

Eric Wood

author
#0 lore raw

I did Warren's RAID-1 howto:
http://togami.com/~warren/guides/remoteraidcrazies/
===========
1. On this system I raid-1 /dev/hda and /dev/hdc together.

And I'm getting these errors during the copy process.
hdc: dma_intr: error=0x84 { DriveStatusError BadCRC }
hdc: dma_intr: status=0x51 { DriveReady SeekComplete Error }

Come to find out Fedore Core 1 put's the "ide-scsi" in the second ide channel since I've got a CDRW there (hdd). Doing a 'rmmod ide-scsi' took care of all the dma errors and the copy process goes through fine. So I removed the "ide-scsi" from grub too.

I assume that ide-scsi on a same channel as a raid-1 member is a big no-no? Maybe I should be putting raid devices on the same channel now so that dma is at it's highest setting for both devices.
===========

===========
2. On another system with the same raid-1 setup, I'm getting kernel errors:
kernel: Unable to handle kernel NULL pointer dereference at virtual
address 00000015
kernel: printing eip:
kernel: c0159772
kernel: *pde = 04f30067
kernel: *pte = 00000000
kernel: Oops: 0000, etc. ,etc.

So I decided to redo the swap partition (which is ARRAY /dev/md3 devices=/dev/hdd3,/dev/hda3):

# swapoff -a
# mdadm --stop --scan
# sync; mkswap /dev/md3
mkswap: error: swap area needs to be at least 40kB
Usage: mkswap [-c] [-v0|-v1] [-pPAGESZ] /dev/name [blocks]

What I don't understand is that the 3rd partion of both drives which are identical have 522112 blocks available:

# sfdisk -l /dev/hda

Disk /dev/hda: 4865 cylinders, 255 heads, 63 sectors/track Units = cylinders of 8225280 bytes, blocks of 1024 bytes, counting from 0

Device Boot Start End #cyls #blocks Id System

/dev/hda1   *      0+     12      13-    104391   fd  Linux raid autodetect
/dev/hda2         13     904     892    7164990   fd  Linux raid autodetect
/dev/hda3        905     969      65     522112+  fd  Linux raid autodetect
/dev/hda4        970    4864    3895   31286587+  fd  Linux raid autodetect
# sfdisk -l /dev/hdd

Disk /dev/hdd: 4865 cylinders, 255 heads, 63 sectors/track Units = cylinders of 8225280 bytes, blocks of 1024 bytes, counting from 0

Device Boot Start End #cyls #blocks Id System

/dev/hdd1   *      0+     12      13-    104391   fd  Linux raid autodetect
/dev/hdd2         13     904     892    7164990   fd  Linux raid autodetect
/dev/hdd3        905     969      65     522112+  fd  Linux raid autodetect
/dev/hdd4        970    4864    3895   31286587+  fd  Linux raid autodetect

I'll trying removing the swap line out of /etc/fstab and reboot, and try and add it back but I have a feeling that won't work. Any other ideas?
===========

-Eric Wood

#1 lore raw
Quoted 10 lines · Eric Wood

I did Warren's RAID-1 howto:
http://togami.com/~warren/guides/remoteraidcrazies/
===========
1. On this system I raid-1 /dev/hda and /dev/hdc together.

And I'm getting these errors during the copy process.
hdc: dma_intr: error=0x84 { DriveStatusError BadCRC }
hdc: dma_intr: status=0x51 { DriveReady SeekComplete Error }

If you haven't already, then it may be worth checking the output of smartctl -a /dev/hdc - just to satisfy yourself that the drive is feeling happy with itself...

http://smartmontools.sourceforge.net/

Tim.

author
#2 lore raw
In reply to Eric Wood

Okay, Catalin showed me my goof on the mkswap problem. So maybe redoing the swap will keep the kernel from panicing any more.
-Eric Wood

----- Original Message -----
From: "Eric Wood"

Quoted 2 lines
# swapoff -a
# mdadm --stop --scan

----- Original Message -----
From: "Catalin BOIE"> > # swapoff -a

Quoted 4 lines
Quoted 1 line
# mdadm --stop --scan

Why did you stopped the array?
It must be started when you do mkswap /dev/md3.

Ah, your absolutely right! Duh!!

Thanks,
-eric wood

#3 lore raw
In reply to Eric Wood
Quoted 8 lines · Eric Wood

I did Warren's RAID-1 howto:
http://togami.com/~warren/guides/remoteraidcrazies/
===========
1. On this system I raid-1 /dev/hda and /dev/hdc together.

And I'm getting these errors during the copy process.
hdc: dma_intr: error=0x84 { DriveStatusError BadCRC }
hdc: dma_intr: status=0x51 { DriveReady SeekComplete Error }

Others have pointed out that ide-scsi shouldn't be the cause of this, but no one seems to have noted the meaning of these errors.

Specifically, the BadCRC error says that the data transfer across the IDE bus was corrupted, usually a sign that your data cable is too long.

You may want to look into that if this is more than a transient problem.

Daniel

Signature · 3 lines
I have always detested the belief that sex is the chief bond
between man and woman. Friendship is far more human.
        -- Agnes Smedley