ata: pata_samsung_cf: Use devm_clk_get()
PATCH v2 1/1 ata: pata_samsung_cf: Use devm_clk_get()
Use devm_clk_get() rather than clk_get() to make cleanup paths more simple.
Signed-off-by Jingoo Han <[email protected]>
---
Changes since v1:
- modified the commit message
drivers/ata/pata_samsung_cf.c | 4 +--- 1 files changed, 1 insertions(+), 3 deletions(-)
drivers/ata/pata_samsung_cf.c +1 -3
@@ -512,7 +512,7 @@ static int __init pata_s3c_probe(struct platform_device *pdev)return -ENOMEM ; } - info->clk =clk_get (&pdev->dev,"cfcon" ); + info->clk =devm_clk_get (&pdev->dev,"cfcon" );if (IS_ERR (info->clk)) {dev_err (dev,"failed to get access to cf controller clock\n" ); ret =PTR_ERR (info->clk);
@@ -589,7 +589,6 @@ static int __init pata_s3c_probe(struct platform_device *pdev) stop_clk:clk_disable (info->clk); -clk_put (info->clk);return ret; }
@@ -601,7 +600,6 @@ static int __exit pata_s3c_remove(struct platform_device *pdev)ata_host_detach (host);clk_disable (info->clk); -clk_put (info->clk);return 0 ; }
Signature · 1 line