nvmet: report backend transport errors as path errors

PATCH Applied Gleb Chesnokov 3 participants 3 messages Nov 13 – Nov 20

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

PATCH 1/1 nvmet: report backend transport errors as path errors

The block backend maps BLK_STS_TRANSPORT to NVME_SC_INTERNAL with DNR set. This discards the backend's transport error classification. A Linux native multipath host completes the request before considering path failover, even if another controller can still access the namespace.

Map BLK_STS_TRANSPORT to NVME_SC_INTERNAL_PATH_ERROR without DNR instead. The transport failure is behind the controller, so report an internal path error rather than a host path error. Associate the error log entry with the namespace, as for the existing access-denied status.

This allows otherwise retryable native multipath requests to reach path error handling.

---
OpenAI Codex assisted with the code analysis, patch and changelog.

 drivers/nvme/target/io-cmd-bdev.c | 4 ++++
 1 file changed, 4 insertions(+)
drivers/nvme/target/io-cmd-bdev.c +4 -0
index 72618dced191..da640b8e8241 100644
@@ -167,6 +167,10 @@ u16 blk_to_nvme_status(struct nvmet_req *req, blk_status_t blk_sts)
 		status = NVME_SC_ACCESS_DENIED;
 		req->error_loc = offsetof(struct nvme_rw_command, nsid);
 		break;
+	case BLK_STS_TRANSPORT:
+		status = NVME_SC_INTERNAL_PATH_ERROR;
+		req->error_loc = offsetof(struct nvme_rw_command, nsid);
+		break;
 	case BLK_STS_IOERR:
 	default:
 		status = NVME_SC_INTERNAL | NVME_STATUS_DNR;

base-commit: 7e1392a42ea288d70a266f6553fe06f57f8647ea

Signature · 1 line
2.56.0
maintainer Reviewed-by on v1 1/1
#1 lore raw
Quoted 5 lines · Gleb Chesnokov

The block backend maps BLK_STS_TRANSPORT to NVME_SC_INTERNAL with DNR set. This discards the backend's transport error classification. A Linux native multipath host completes the request before considering path failover, even if another controller can still access the namespace.

Quoted 7 lines

Map BLK_STS_TRANSPORT to NVME_SC_INTERNAL_PATH_ERROR without DNR instead. The transport failure is behind the controller, so report an internal path error rather than a host path error. Associate the error log entry with the namespace, as for the existing access-denied status.

This allows otherwise retryable native multipath requests to reach path error handling.

Looks good:

maintainer Applied
#2 lore raw
In reply to Gleb Chesnokov
Quoted 11 lines · Gleb Chesnokov

The block backend maps BLK_STS_TRANSPORT to NVME_SC_INTERNAL with DNR set. This discards the backend's transport error classification. A Linux native multipath host completes the request before considering path failover, even if another controller can still access the namespace.

Map BLK_STS_TRANSPORT to NVME_SC_INTERNAL_PATH_ERROR without DNR instead. The transport failure is behind the controller, so report an internal path error rather than a host path error. Associate the error log entry with the namespace, as for the existing access-denied status.

[...]

Thanks, applied to nvme-7.5.

[1/1] nvmet: report backend transport errors as path errors

      commit: 3b90e37012c0c5297ccbd7b531287b943c818bba

--
Keith Busch <[email protected]>