Hi:
1. Could anyone use impitool sel list to read values after calling the sd_journal_send method?
2. Calling the startThresholdEventMonitor method of the phosphor-sel-logger module, why get the values of max, min, sensorVal are all 0? But I can get the correct values through dbus. Thanks

#1 lore raw
Quoted 2 lines · George Liu

Hi:
1. Could anyone use impitool sel list to read values after calling the sd_journal_send method?

No, not really. sd_journal_send only adds a log entry with metadata to the journal.

phosphor-sel-logger adds special metadata to identify the entry as an IPMI sel record. A special implementation of the 'Get SEL Entry' IPMI command is needed to find the journal entries with SEL metadata and construct the IPMI SEL records. An example implementation is here: https://gerrit.openbmc-project.xyz/c/openbmc/intel-ipmi-oem/+/16280.

Quoted 1 line

2. Calling the startThresholdEventMonitor method of the phosphor-sel-logger module, why get the values of max, min, sensorVal are all 0? But I can get the correct values through dbus.

Calling startThresholdEventMonitor() should start a D-Bus match to watch for any changes to 'xyz.openbmc_project.Sensor.Threshold' properties. The 'Alarm' properties are used to know when a sensor threshold is crossed and log that event automatically.

When the match is triggered, the callback uses the same bus and path to get the properties from the 'xyz.openbmc_project.Sensor.Value' interface which has the MaxValue, MinValue, and Value properties for the sensor.

So, is the issue you see that after the match is triggered and the 'xyz.openbmc_project.Sensor.Value' properties are read from that path, they are all 0, but if you manually read the properties from the same path, they are correct?

Quoted 3 lines

Thanks