2.5.39 - make MCE options arch dependent

PATCH In review Phil Oester 4 participants 4 messages Sep 29, 2002 – Sep 30, 2002

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 2.5.39 - make MCE options arch dependent

No need to see P4 or Athlon options if you don't have one...

-Phil

arch/i386/config.in Sun Sep 29 15:55:44 2002 renamed from arch/i386/config.in Fri Sep 27 14:49:42 2002 +6 -2
@@ -187,8 +187,12 @@
 fi
 
 bool 'Machine Check Exception' CONFIG_X86_MCE
-dep_bool 'Check for non-fatal errors on Athlon/Duron' CONFIG_X86_MCE_NONFATAL $CONFIG_X86_MCE
-dep_bool 'check for P4 thermal throttling interrupt.' CONFIG_X86_MCE_P4THERMAL $CONFIG_X86_MCE $CONFIG_X86_UP_APIC
+if [ "$CONFIG_MK7" = "y" ]; then
+   dep_bool 'Check for non-fatal errors on Athlon/Duron' CONFIG_X86_MCE_NONFATAL $CONFIG_X86_MCE
+fi
+if [ "$CONFIG_MPENTIUM4" = "y" ]; then
+   dep_bool 'Check for P4 thermal throttling interrupt' CONFIG_X86_MCE_P4THERMAL $CONFIG_X86_MCE $CONFIG_X86_UP_APIC
+fi 
 
#1 lore raw
Quoted 3 lines · Phil Oester

No need to see P4 or Athlon options if you don't have one...

-Phil

Broken. Vendor kernels compile for 386, but include both these options, so the same kernel can run on P4/Athlon and use these options.

Dave

Signature · 2 lines
| Dave Jones.        http://www.codemonkey.org.uk
| SuSE Labs
#2 lore raw
In reply to Phil Oester
Quoted 6 lines · Phil Oester

No need to see P4 or Athlon options if you don't have one...

arch/i386/config.in Sun Sep 29 15:55:44 2002 renamed from arch/i386/config.in Fri Sep 27 14:49:42 2002 +0 -0
@@ -187,8 +187,12 @@
 fi

arch/i386/config.in Sun Sep 29 15:55:44 2002 line 195

Quoted 10 lines
arch/i386/config.in Sun Sep 29 15:55:44 2002 renamed from arch/i386/config.in Fri Sep 27 14:49:42 2002 +6 -2
 
 bool 'Machine Check Exception' CONFIG_X86_MCE
-dep_bool 'Check for non-fatal errors on Athlon/Duron' CONFIG_X86_MCE_NONFATAL $CONFIG_X86_MCE
-dep_bool 'check for P4 thermal throttling interrupt.' CONFIG_X86_MCE_P4THERMAL $CONFIG_X86_MCE $CONFIG_X86_UP_APIC
+if [ "$CONFIG_MK7" = "y" ]; then
+   dep_bool 'Check for non-fatal errors on Athlon/Duron' CONFIG_X86_MCE_NONFATAL $CONFIG_X86_MCE
+fi
+if [ "$CONFIG_MPENTIUM4" = "y" ]; then
+   dep_bool 'Check for P4 thermal throttling interrupt' CONFIG_X86_MCE_P4THERMAL $CONFIG_X86_MCE $CONFIG_X86_UP_APIC
+fi 

But now I can't build a "generic" kernel which supports both these features.

				Regards,

					Richard....
Permanent: [email protected]
Current:   [email protected]
#3 lore raw
In reply to Phil Oester
Quoted 1 line · Phil Oester

No need to see P4 or Athlon options if you don't have one..

This makes little sense. The P4 and K7 MCE handling can be built into any kernel tree and will correctly work. That means you can build things into a generic kernel not just a per processor kernel, which for any number of systems becomes unmanagable