HDSP matrix mixer
Hi,
I started implementing a GUI for the HDSP matrix mixer using the fltk toolkit. I want to get as close as possible to the TotalMix RME application, thus I'm trying to implement hardware metering using the Peak and RMS HDSP registers. The peak value covers the whole int range, and seems quite usable to me (though it would need some king of logarithmic scaling), but the rms value, despite being an integer64, only covers a very narrow range. What is the correct way to handle those values ?
Regards,
Thomas
-------------------------------------------------------
This SF.net email is sponsored by: Get the new Palm Tungsten T handheld. Power & Color in a compact size!
http://ads.sourceforge.net/cgi-bin/redirect.pl?palm0002en
Quoted 4 lines
I started implementing a GUI for the HDSP matrix mixer using the fltk toolkit. I want to get as close as possible to the TotalMix RME application, thus I'm trying to implement hardware metering using the Peak and RMS HDSP registers. The peak value covers the whole int range,
actually, no. it covers the range from 2^8 .. (2^32)-1. you need to first adjust the value to a true 24 bit value, or more conveniently, a normalized 32 bit float. here is the code from JACK which does this (it could be optimized, i would expect):
#define SAMPLE_MAX_24BIT 8388607.0f
floatval = (peakval >> 8) / SAMPLE_MAX_24BIT;Quoted 4 lines
and seems quite usable to me (though it would need some king of logarithmic scaling), but the rms value, despite being an integer64, only covers a very narrow range. What is the correct way to handle those values ?
i don't know enough about the rms values to comment on this. i would imagine that the RMS values are in dB[something], and thus would span a rather narrow numerical range, but actually represent a very large range because of the logarithmic scaling. i can try to dig through the emails i have where martin from rme described what the rms meters do.
--p
-------------------------------------------------------
This SF.net email is sponsored by: Get the new Palm Tungsten T handheld. Power & Color in a compact size!
http://ads.sourceforge.net/cgi-bin/redirect.pl?palm0002en
Quoted 4 lines
#define SAMPLE_MAX_24BIT 8388607.0ffloatval = (peakval >> 8) / SAMPLE_MAX_24BIT;
Thanks, my meters look better now :)
Quoted 1 line
i don't know enough about the rms values to comment on this. i would
Neither do I...
Quoted 5 lines
imagine that the RMS values are in dB[something], and thus would span a rather narrow numerical range, but actually represent a very large range because of the logarithmic scaling. i can try to dig through the emails i have where martin from rme described what the rms meters do.
Please do, I would really appreciate any information on the subject.
Thomas
-------------------------------------------------------
This SF.net email is sponsored by: Get the new Palm Tungsten T handheld. Power & Color in a compact size!
http://ads.sourceforge.net/cgi-bin/redirect.pl?palm0002en