Skip to contentSkip to conversation

bdi2000 reset target failed

U-Boot-Users Hinko Kocevar 2 participants 3 messages Feb 7, 2005 – Feb 9, 2005

lore
Share & tools
lore
#0 lore raw

Hi,
After good start I'm back to square one in my debugging session. After a while and with help on this list I managed to get target resetted and did some tests. After a while the same problem appeared - BDI2000 can not reset target and fails with message:
- TARGET: processing reset request
- TARGET: BDI asserts RESET and TRST
- TARGET: BDI removed TRST
- TARGET: Bypass check: 0x000000001 => 0x00FFFFFF
- TARGET: JTAG exists check failed
# TARGET: resetting target failed
# JTAG: communication with target failed
- TARGET: target will be restarted in 10 sec

I'm pretty sure that JTAG cable for first target is OK, since it was working a while ago, and I also tested BDI2000 with another PXA target and the same error emerges there (with this target I have direct connection between BDI2000 and target JTAG).

Any help is appreciated...

regards,
hk

Signature · 5 lines
hinko <dot> kocevar <at> iskramedical <dot> si
Hinko Kocevar, embedded systems developer
Iskra Medical d.o.o., Stegne 23, 1k LJ, SLO-EU

	"A? r?n"	|	[Analects XII:22]
#1 lore raw

Hi

Quoted 1 line

- TARGET: Bypass check: 0x000000001 => 0x00FFFFFF

I'd say that if the reset works O.K., you should check the TDI and TDO lines. It looks like one of them (probably TDO) is opened (HiZ) or connected to Vcc.

Regards,
Matej

#2 lore raw
In reply to Hinko Kocevar
Quoted 3 lines · Hinko Kocevar

- TARGET: Bypass check: 0x000000001 => 0x00FFFFFF
- TARGET: JTAG exists check failed
# TARGET: resetting target failed

Hmm, somehow config file on tftp has been truncated to zero and replacing it with fresh copy solved the problem.

Signature · 5 lines
hinko <dot> kocevar <at> iskramedical <dot> si
Hinko Kocevar, embedded systems developer
Iskra Medical d.o.o., Stegne 23, 1k LJ, SLO-EU

	"A? r?n"	|	[Analects XII:22]