Make shutdown use strings instead of codes
PATCH 1/2 Make shutdown use strings instead of codes
This patch changes the shutdown driver and xend to use strings instead of codes for signaling a shutdown request.
Also, we fix the return code for the shutdown notifier, so other notifiers will get to run ;)
linux-2.6-xen-sparse/arch/xen/kernel/reboot.c +28 -16
@@ -247,19 +247,31 @@ { static DECLARE_WORK(shutdown_work, __shutdown_handler, NULL); -int type =-1 ; - -if (!xenbus_scanf ("control" ,"shutdown" ,"%i" , &type)) { -printk ("Unable to read code in control/shutdown\n" ); +char *str; +unsigned int len; + + str = (char *)xenbus_read ("control" ,"shutdown" , &len); + +if (! len) {return ; - }; + }xenbus_printf ("control" ,"shutdown" ,"%i" ,SHUTDOWN_INVALID ); -if ((type ==SHUTDOWN_POWEROFF ) || - (type ==SHUTDOWN_REBOOT ) || - (type ==SHUTDOWN_SUSPEND )) { - shutting_down = type; +if (strncmp (str,"poweroff" , len) ==0 ) { + shutting_down =SHUTDOWN_POWEROFF ; + }else if (strncmp (str,"reboot" , len) ==0 ) { + shutting_down =SHUTDOWN_REBOOT ; + }else if (strncmp (str,"suspend" , len) ==0 ) { + shutting_down =SHUTDOWN_SUSPEND ; + }else { +printk ("Ignoring shutdown request: %s\n" , str); + shutting_down =SHUTDOWN_INVALID ; + } + +kfree (str); + +if (shutting_down !=SHUTDOWN_INVALID ) {schedule_work (&shutdown_work); }
@@ -271,7 +283,7 @@char sysrq_key ='\0' ;if (!xenbus_scanf ("control" ,"sysrq" ,"%c" , &sysrq_key)) { -printk ("Unable to read sysrq code in control/sysrq\n" ); +printk (KERN_ERR "Unable to read sysrq code in control/sysrq\n" );return ; }
@@ -319,16 +331,16 @@up (&xenbus_lock);if (err1) { -printk ("Failed to set shutdown watcher\n" ); +printk (KERN_ERR "Failed to set shutdown watcher\n" ); }#ifdef CONFIG_MAGIC_SYSRQ if (err2) { -printk ("Failed to set sysrq watcher\n" ); - } -#endif - -return NOTIFY_STOP ; +printk (KERN_ERR "Failed to set sysrq watcher\n" ); + } +#endif + +return NOTIFY_DONE ; }static int __init setup_shutdown_event (void )
tools/python/xen/xend/XendDomainInfo.py +2 -11
@@ -50,14 +50,6 @@ DOMAIN_REBOOT : "reboot", DOMAIN_SUSPEND : "suspend", DOMAIN_CRASH : "crash", - } - -"""Map shutdown reasons to codes -""" -shutdown_codes = { - 'poweroff' : DOMAIN_POWEROFF, - 'reboot' : DOMAIN_REBOOT, - 'suspend' : DOMAIN_SUSPEND, } RESTART_ALWAYS = 'always'
@@ -939,11 +931,10 @@ self.channel.writeRequest(msg) def shutdown(self, reason): - reasonid = shutdown_codes.get(reason) - if reasonid == None: + if not reason in shutdown_reasons.values(): raise XendError('invalid reason:' + reason) db = self.db.addChild("/control"); - db['shutdown'] = '%i' % reasonid; + db['shutdown'] = reason; db.saveDB(save=True); if not reason in ['suspend']: self.shutdown_pending = {'start':time.time(), 'reason':reason}
Signature · 5 lines
-- Dan Smith IBM Linux Technology Center Open Hypervisor Team email: [email protected]
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xensource.com/xen-devel
Quoted 2 lines · Dan Smith
This patch changes the shutdown driver and xend to use strings instead of codes for signaling a shutdown request.
Thanks!
+ printk("Ignoring shutdown request: %s\n", str);
+ shutting_down = SHUTDOWN_INVALID;
You missed an opportunity for a KERN_WARN or a KERN_INFO here - I notice you added them everywhere else.
Cheers,
Mark
Quoted 2 lines · Dan Smith
This patch changes the shutdown driver and xend to use strings instead of codes for signaling a shutdown request.
Commenting on this:
+ unsigned int len;
+
+ str = (char *)xenbus_read("control", "shutdown", &len);
+
+ if (! len) {
return;- };
+ }
xenbus_read will always nul-terminate the string it receives, and you should *never* test len as an indication of error!
It should be:
str = xenbus_read("control", "shutdown", NULL);
if (IS_ERR(str))
return;Cheers!
Rusty.
Signature · 1 line
A bad analogy is like a leaky screwdriver -- Richard Braakman