EMC CX LUN problem
Hi,
I'm trying to configure a new emc cx storage, I have the following:
2 server, each server has a qla2462 dual port hba each qla2462 is connected to a switch (only one switch) 1 emc cx storage with 4 path connected to the switch
I defined two lun on the storage however I'm able to see only one LUN
multipath -l show the following:
multipath -l
mail (36006016086f01600e46f567adb8cda11)
[size=150 GB][features="1 queue_if_no_path"][hwhandler="1 emc"] \_ round-robin 0 [active]
\_ 1:0:1:0 sdd 8:48 [active][ready]
\_ 1:0:1:1 sde 8:64 [active][ready]
\_ 2:0:1:0 sdh 8:112 [active][ready]
\_ 2:0:1:1 sdi 8:128 [active][ready]
\_ round-robin 0 [enabled]
\_ 2:0:0:0 sdf 8:80 [active][ready] \_ 1:0:0:0 sdb 8:16 [active][ready] \_ 1:0:0:1 sdc 8:32 [active][ready] \_ 2:0:0:1 sdg 8:96 [active][ready]
this seems correct for my configuration however I'm not able to see the other LUN, tommorrow I'll try to connect the 2 server directly to the storage, some other hint?
from dmesg:
QLogic Fibre Channel HBA Driver
ACPI: PCI Interrupt 0000:08:00.0[A] -> GSI 16 (level, low) -> IRQ 16 qla2400 0000:08:00.0: Found an ISP2432, irq 16, iobase 0xf881a000 qla2400 0000:08:00.0: Configuring PCI space...
PCI: Setting latency timer of device 0000:08:00.0 to 64 qla2400 0000:08:00.0: Configure NVRAM parameters...
qla2400 0000:08:00.0: Verifying loaded RISC code...
qla2400 0000:08:00.0: Allocated (1061 KB) for firmware dump... qla2400 0000:08:00.0: Waiting for LIP to complete...
qla2400 0000:08:00.0: LIP reset occured (f8f7).
qla2400 0000:08:00.0: LIP occured (f8f7).
qla2400 0000:08:00.0: LOOP UP detected (2 Gbps).
qla2400 0000:08:00.0: Topology - (F_Port), Host Loop address 0x0 scsi1 : qla2xxx
qla2400 0000:08:00.0:
QLogic Fibre Channel HBA Driver: 8.01.04-k-fw
QLogic QLE2462 - PCI-Express to 4Gb FC, Dual Channel
ISP2432: PCIe (2.5Gb/s x4) @ 0000:08:00.0 hdma-, host#=1, fw=4.00.16 [IP]
ACPI: PCI Interrupt 0000:08:00.1[B] -> GSI 17 (level, low) -> IRQ 20
Vendor: DGC Model: RAID 5 Rev: 0219
Type: Direct-Access ANSI SCSI revision: 04
SCSI device sdb: 314572800 512-byte hdwr sectors (161061 MB)
sdb: test WP failed, assume Write Enabled
sdb: asking for cache data failed
sdb: assuming drive cache: write through
qla2400 0000:08:00.1: Found an ISP2432, irq 20, iobase 0xf881c000 SCSI device sdb: 314572800 512-byte hdwr sectors (161061 MB) qla2400 0000:08:00.1: Configuring PCI space...
PCI: Setting latency timer of device 0000:08:00.1 to 64
sdb: test WP failed, assume Write Enabled
qla2400 0000:08:00.1: Configure NVRAM parameters...
sdb: asking for cache data failed
sdb: assuming drive cache: write through
sdb:<6>sd 1:0:0:0: Device not ready.end_request: I/O error, dev sdb, sector 0
Buffer I/O error on device sdb, logical block 0
sd 1:0:0:0: Device not ready.end_request: I/O error, dev sdb, sector 0
Buffer I/O error on device sdb, logical block 0
unable to read partition table
sd 1:0:0:0: Attached scsi disk sdb
Vendor: DGC Model: RAID 5 Rev: 0219
Type: Direct-Access ANSI SCSI revision: 04
qla2400 0000:08:00.1: Verifying loaded RISC code...
SCSI device sdc: 314572800 512-byte hdwr sectors (161061 MB)
sdc: test WP failed, assume Write Enabled
sdc: asking for cache data failed
sdc: assuming drive cache: write through
SCSI device sdc: 314572800 512-byte hdwr sectors (161061 MB)
sdc: test WP failed, assume Write Enabled
sdc: asking for cache data failed
sdc: assuming drive cache: write through
sdc:<6>sd 1:0:0:1: Device not ready.end_request: I/O error, dev sdc, sector 0
Buffer I/O error on device sdc, logical block 0
sd 1:0:0:1: Device not ready.end_request: I/O error, dev sdc, sector 0
Buffer I/O error on device sdc, logical block 0
unable to read partition table
sd 1:0:0:1: Attached scsi disk sdc
Vendor: DGC Model: RAID 5 Rev: 0219
Type: Direct-Access ANSI SCSI revision: 04
SCSI device sdd: 314572800 512-byte hdwr sectors (161061 MB)
sdd: Write Protect is off
sdd: Mode Sense: 87 00 00 08
SCSI device sdd: drive cache: write through
SCSI device sdd: 314572800 512-byte hdwr sectors (161061 MB)
sdd: Write Protect is off
sdd: Mode Sense: 87 00 00 08
SCSI device sdd: drive cache: write through
sdd: unknown partition table
sd 1:0:1:0: Attached scsi disk sdd
Vendor: DGC Model: RAID 5 Rev: 0219
Type: Direct-Access ANSI SCSI revision: 04
SCSI device sde: 314572800 512-byte hdwr sectors (161061 MB)
sde: Write Protect is off
sde: Mode Sense: 87 00 00 08
SCSI device sde: drive cache: write through
SCSI device sde: 314572800 512-byte hdwr sectors (161061 MB)
sde: Write Protect is off
sde: Mode Sense: 87 00 00 08
SCSI device sde: drive cache: write through
sde: unknown partition table
sd 1:0:1:1: Attached scsi disk sde
qla2400 0000:08:00.1: Allocated (1061 KB) for firmware dump... qla2400 0000:08:00.1: Waiting for LIP to complete...
qla2400 0000:08:00.1: LIP reset occured (f8f7).
qla2400 0000:08:00.1: LIP occured (f8f7).
qla2400 0000:08:00.1: LOOP UP detected (2 Gbps).
qla2400 0000:08:00.1: Topology - (F_Port), Host Loop address 0x0 scsi2 : qla2xxx
qla2400 0000:08:00.1:
QLogic Fibre Channel HBA Driver: 8.01.04-k-fw
QLogic QLE2462 - PCI-Express to 4Gb FC, Dual Channel
ISP2432: PCIe (2.5Gb/s x4) @ 0000:08:00.1 hdma-, host#=2, fw=4.00.16 [IP]
Vendor: DGC Model: RAID 5 Rev: 0219
Type: Direct-Access ANSI SCSI revision: 04
SCSI device sdf: 314572800 512-byte hdwr sectors (161061 MB)
sdf: test WP failed, assume Write Enabled
sdf: asking for cache data failed
sdf: assuming drive cache: write through
SCSI device sdf: 314572800 512-byte hdwr sectors (161061 MB)
sdf: test WP failed, assume Write Enabled
sdf: asking for cache data failed
sdf: assuming drive cache: write through
sdf:<6>sd 2:0:0:0: Device not ready.end_request: I/O error, dev sdf, sector 0
Buffer I/O error on device sdf, logical block 0
sd 2:0:0:0: Device not ready.end_request: I/O error, dev sdf, sector 0
Buffer I/O error on device sdf, logical block 0
unable to read partition table
sd 2:0:0:0: Attached scsi disk sdf
Vendor: DGC Model: RAID 5 Rev: 0219
Type: Direct-Access ANSI SCSI revision: 04
SCSI device sdg: 314572800 512-byte hdwr sectors (161061 MB)
sdg: test WP failed, assume Write Enabled
sdg: asking for cache data failed
sdg: assuming drive cache: write through
SCSI device sdg: 314572800 512-byte hdwr sectors (161061 MB)
sdg: test WP failed, assume Write Enabled
sdg: asking for cache data failed
sdg: assuming drive cache: write through
sdg:<6>sd 2:0:0:1: Device not ready.end_request: I/O error, dev sdg, sector 0
Buffer I/O error on device sdg, logical block 0
sd 2:0:0:1: Device not ready.end_request: I/O error, dev sdg, sector 0
Buffer I/O error on device sdg, logical block 0
unable to read partition table
sd 2:0:0:1: Attached scsi disk sdg
Vendor: DGC Model: RAID 5 Rev: 0219
Type: Direct-Access ANSI SCSI revision: 04
SCSI device sdh: 314572800 512-byte hdwr sectors (161061 MB)
sdh: Write Protect is off
sdh: Mode Sense: 87 00 00 08
SCSI device sdh: drive cache: write through
SCSI device sdh: 314572800 512-byte hdwr sectors (161061 MB)
sdh: Write Protect is off
sdh: Mode Sense: 87 00 00 08
SCSI device sdh: drive cache: write through
sdh: unknown partition table
sd 2:0:1:0: Attached scsi disk sdh
Vendor: DGC Model: RAID 5 Rev: 0219
Type: Direct-Access ANSI SCSI revision: 04
SCSI device sdi: 314572800 512-byte hdwr sectors (161061 MB)
sdi: Write Protect is off
sdi: Mode Sense: 87 00 00 08
SCSI device sdi: drive cache: write through
SCSI device sdi: 314572800 512-byte hdwr sectors (161061 MB)
sdi: Write Protect is off
sdi: Mode Sense: 87 00 00 08
SCSI device sdi: drive cache: write through
sdi: unknown partition table
sd 2:0:1:1: Attached scsi disk sdi
it seems as if only one LUN was defined but the management software confirm that two LUN was created,
any help would be appreciated,
thanks
Nicola
Quoted 21 lines · Nicola Murino
Hi,
I'm trying to configure a new emc cx storage, I have the following:
2 server, each server has a qla2462 dual port hba each qla2462 is connected to a switch (only one switch) 1 emc cx storage with 4 path connected to the switch
I defined two lun on the storage however I'm able to see only one LUN
multipath -l show the following:
multipath -l
mail (36006016086f01600e46f567adb8cda11)
[size=150 GB][features="1 queue_if_no_path"][hwhandler="1 emc"] \_ round-robin 0 [active]
\_ 1:0:1:0 sdd 8:48 [active][ready]
\_ 1:0:1:1 sde 8:64 [active][ready]
\_ 2:0:1:0 sdh 8:112 [active][ready]
\_ 2:0:1:1 sdi 8:128 [active][ready]
\_ round-robin 0 [enabled]
Quoted 5 lines
\_ 2:0:0:0 sdf 8:80 [active][ready] \_ 1:0:0:0 sdb 8:16 [active][ready] \_ 1:0:0:1 sdc 8:32 [active][ready] \_ 2:0:0:1 sdg 8:96 [active][ready]
i could be off in the weeds here, but this output looks wrong. the host:channel:target:lun numbers listed there suggest your cx is indeed surfacing luns 0 and 1, but multipath is grouping them under a single target ID.
i think emc engineers monitor this list; perhaps they can help.
also, look at this if you havent already (there's a section on clariion cx's), and feel free to add your findings.
http://christophe.varoqui.free.fr/wiki/wakka.php?wiki=TestedEnvironments
hope that helps,
brian
Hi,
Quoted 7 lines
Quoted 7 lines
I'm trying to configure a new emc cx storage, I have the following:
I defined two lun on the storage however I'm able to see only one LUN
multipath -l show the following:
Quoted 16 lines
Quoted 9 lines
multipath -l
mail (36006016086f01600e46f567adb8cda11)
[size=150 GB][features="1 queue_if_no_path"][hwhandler="1 emc"] \_ round-robin 0 [active]
\_ 1:0:1:0 sdd 8:48 [active][ready]
\_ 1:0:1:1 sde 8:64 [active][ready]
\_ 2:0:1:0 sdh 8:112 [active][ready]
\_ 2:0:1:1 sdi 8:128 [active][ready]
\_ round-robin 0 [enabled]Quoted 7 lines
\_ 2:0:0:0 sdf 8:80 [active][ready] \_ 1:0:0:0 sdb 8:16 [active][ready] \_ 1:0:0:1 sdc 8:32 [active][ready] \_ 2:0:0:1 sdg 8:96 [active][ready]
did you probably just share one raid group via 2 LUNs? Then the output of multipath is imho indeed right. For me it shows the setup you've described - one raidgroup, shared via 2 LUNs (usually one per default on SP A, one on SP B, attached via 2 paths per SP to a switch, accessed from your server via 2 HBAs.
If you have access to the Navisphere cli tool - please post the output of
./navicli -h IP_OF_ONE_OF_YOUR_SPs getlun
I think this will show that my hint is right.
Imho you want to create a second raid group and share it via 2 LUNs, too.
I hope there's nothing wring with the stuff I've written about the EMC/CX in there, if you find anything please let me know - I don't look in there often.
Hope that helps,
best regards
Bernd
Hi thanks all for your help,
I have two raid group, each raid group has two lun, the lun of the first raid group are for a linux cluster, the lun of the second raid group are for a windows cluster,
I installed navicli, this is the output you requested:
./navicli -h 192.168.2.11 getlun
Statistics logging is disabled.
Certain fields are not printed if statistics
logging is not enabled.
LOGICAL UNIT NUMBER 0
Prefetch size (blocks) = 0 Prefetch multiplier = 4 Segment size (blocks) = 0 Segment multiplier = 4 Maximum prefetch (blocks) = 4096
Prefetch Disable Size (blocks) = 4097
Prefetch idle count = 40
Variable length prefetching YES
Prefetched data retained YES
Read cache configured according to
specified parameters.
Total Hard Errors: 0 Total Soft Errors: 0 Total Queue Length: 0
Name ql
Minimum latency reads N/A
RAID Type: RAID5 RAIDGroup ID: 0 State: Bound Stripe Crossing: 0 Element Size: 128 Current owner: SP B Offset: 0 Auto-trespass: DISABLED Auto-assign: DISABLED Write cache: ENABLED Read cache: ENABLED Idle Threshold: 0 Idle Delay Time: 20 Write Aside Size: 2048 Default Owner: SP B Rebuild Priority: ASAP Verify Priority: ASAP Prct Reads Forced Flushed: 0 Prct Writes Forced Flushed: 0 Prct Rebuilt: 100 Prct Bound: 100 LUN Capacity(Megabytes): 512000 LUN Capacity(Blocks): 1048576000 UID: 60:06:01:60:86:F0:16:00:BE:5A:CA:73:DB:8C:DA:11 Is Private: NO Snapshots List: None MirrorView Name if any: Not Mirrored
LOGICAL UNIT NUMBER 2
Prefetch size (blocks) = 0 Prefetch multiplier = 4 Segment size (blocks) = 0 Segment multiplier = 4 Maximum prefetch (blocks) = 4096
Prefetch Disable Size (blocks) = 4097
Prefetch idle count = 40
Variable length prefetching YES
Prefetched data retained YES
Read cache configured according to
specified parameters.
Total Hard Errors: 0 Total Soft Errors: 0 Total Queue Length: 0
Name win
Minimum latency reads N/A
RAID Type: RAID5 RAIDGroup ID: 1 State: Bound Stripe Crossing: 0 Element Size: 128 Current owner: SP A Offset: 0 Auto-trespass: DISABLED Auto-assign: DISABLED Write cache: ENABLED Read cache: ENABLED Idle Threshold: 0 Idle Delay Time: 20 Write Aside Size: 2048 Default Owner: SP A Rebuild Priority: ASAP Verify Priority: ASAP Prct Reads Forced Flushed: 0 Prct Writes Forced Flushed: 0 Prct Rebuilt: 100 Prct Bound: 100 LUN Capacity(Megabytes): 819200 LUN Capacity(Blocks): 1677721600 UID: 60:06:01:60:86:F0:16:00:B6:2F:72:8B:DB:8C:DA:11 Is Private: NO Snapshots List: None MirrorView Name if any: Not Mirrored
LOGICAL UNIT NUMBER 3
Prefetch size (blocks) = 0 Prefetch multiplier = 4 Segment size (blocks) = 0 Segment multiplier = 4 Maximum prefetch (blocks) = 4096
Prefetch Disable Size (blocks) = 4097
Prefetch idle count = 40
Variable length prefetching YES
Prefetched data retained YES
Read cache configured according to
specified parameters.
Total Hard Errors: 0 Total Soft Errors: 0 Total Queue Length: 0
Name quorum
Minimum latency reads N/A
RAID Type: RAID5 RAIDGroup ID: 1 State: Bound Stripe Crossing: 0 Element Size: 128 Current owner: SP A Offset: 0 Auto-trespass: DISABLED Auto-assign: DISABLED Write cache: ENABLED Read cache: ENABLED Idle Threshold: 0 Idle Delay Time: 20 Write Aside Size: 2048 Default Owner: SP A Rebuild Priority: ASAP Verify Priority: ASAP Prct Reads Forced Flushed: 0 Prct Writes Forced Flushed: 0 Prct Rebuilt: 100 Prct Bound: 100 LUN Capacity(Megabytes): 5120 LUN Capacity(Blocks): 10485760 UID: 60:06:01:60:86:F0:16:00:FC:D3:8B:91:DB:8C:DA:11 Is Private: NO Snapshots List: None MirrorView Name if any: Not Mirrored
LOGICAL UNIT NUMBER 1
Prefetch size (blocks) = 0 Prefetch multiplier = 4 Segment size (blocks) = 0 Segment multiplier = 4 Maximum prefetch (blocks) = 4096
Prefetch Disable Size (blocks) = 4097
Prefetch idle count = 40
Variable length prefetching YES
Prefetched data retained YES
Read cache configured according to
specified parameters.
Total Hard Errors: 0 Total Soft Errors: 0 Total Queue Length: 0
Name mail
Minimum latency reads N/A
RAID Type: RAID5 RAIDGroup ID: 0 State: Bound Stripe Crossing: 0 Element Size: 128 Current owner: SP B Offset: 0 Auto-trespass: DISABLED Auto-assign: DISABLED Write cache: ENABLED Read cache: ENABLED Idle Threshold: 0 Idle Delay Time: 20 Write Aside Size: 2048 Default Owner: SP B Rebuild Priority: ASAP Verify Priority: ASAP Prct Reads Forced Flushed: 0 Prct Writes Forced Flushed: 0 Prct Rebuilt: 100 Prct Bound: 100 LUN Capacity(Megabytes): 153600 LUN Capacity(Blocks): 314572800 UID: 60:06:01:60:86:F0:16:00:E4:6F:56:7A:DB:8C:DA:11 Is Private: NO Snapshots List: None MirrorView Name if any: Not Mirrored
the output of scsi_id is the same:
server2 block # scsi_id -g -u -s /block/sdb36006016086f01600e46f567adb8cda11
server2 block # scsi_id -g -u -s /block/sdc36006016086f01600e46f567adb8cda11
server2 block # scsi_id -g -u -s /block/sdd36006016086f01600e46f567adb8cda11
server2 block # scsi_id -g -u -s /block/sde36006016086f01600e46f567adb8cda11
server2 block # scsi_id -g -u -s /block/sdf36006016086f01600e46f567adb8cda11
server2 block # scsi_id -g -u -s /block/sdg36006016086f01600e46f567adb8cda11
server2 block # scsi_id -g -u -s /block/sdh36006016086f01600e46f567adb8cda11
server2 block # scsi_id -g -u -s /block/sdi36006016086f01600e46f567adb8cda11
I can see and write only on the LUN called mail, I'm not able to see ql
thanks for your help,
regards
Nicola
Bernd Zeimetz ha scritto:
Quoted 62 lines
Hi,
Quoted 16 lines
Quoted 16 lines
I'm trying to configure a new emc cx storage, I have the following:
I defined two lun on the storage however I'm able to see only one LUN
multipath -l show the following:
multipath -l
mail (36006016086f01600e46f567adb8cda11)
[size=150 GB][features="1 queue_if_no_path"][hwhandler="1 emc"] \_ round-robin 0 [active]
\_ 1:0:1:0 sdd 8:48 [active][ready]
\_ 1:0:1:1 sde 8:64 [active][ready]
\_ 2:0:1:0 sdh 8:112 [active][ready]
\_ 2:0:1:1 sdi 8:128 [active][ready]
\_ round-robin 0 [enabled]Quoted 8 lines
Quoted 8 lines
\_ 2:0:0:0 sdf 8:80 [active][ready] \_ 1:0:0:0 sdb 8:16 [active][ready] \_ 1:0:0:1 sdc 8:32 [active][ready] \_ 2:0:0:1 sdg 8:96 [active][ready]did you probably just share one raid group via 2 LUNs? Then the output of multipath is imho indeed right. For me it shows the setup you've described - one raidgroup, shared via 2 LUNs (usually one per default on SP A, one on SP B, attached via 2 paths per SP to a switch, accessed from your server via 2 HBAs.
If you have access to the Navisphere cli tool - please post the output of./navicli -h
IP_OF_ONE_OF_YOUR_SPsgetlunI think this will show that my hint is right.
Imho you want to create a second raid group and share it via 2 LUNs, too.I hope there's nothing wring with the stuff I've written about the EMC/CX in there, if you find anything please let me know - I don't look in there often.
Hope that helps,
best regards
Bernd
--
dm-devel mailing list
[email protected]
https://www.redhat.com/mailman/listinfo/dm-devel
Brian Wong ha scritto:
Quoted 30 lines · Nicola Murino
Quoted 22 lines
Hi,
I'm trying to configure a new emc cx storage, I have the following:
2 server, each server has a qla2462 dual port hba each qla2462 is connected to a switch (only one switch) 1 emc cx storage with 4 path connected to the switch
I defined two lun on the storage however I'm able to see only one LUN
multipath -l show the following:
multipath -l
mail (36006016086f01600e46f567adb8cda11)
[size=150 GB][features="1 queue_if_no_path"][hwhandler="1 emc"] \_ round-robin 0 [active]
\_ 1:0:1:0 sdd 8:48 [active][ready]
\_ 1:0:1:1 sde 8:64 [active][ready]
\_ 2:0:1:0 sdh 8:112 [active][ready]
\_ 2:0:1:1 sdi 8:128 [active][ready]
\_ round-robin 0 [enabled]Quoted 6 lines
\_ 2:0:0:0 sdf 8:80 [active][ready] \_ 1:0:0:0 sdb 8:16 [active][ready] \_ 1:0:0:1 sdc 8:32 [active][ready] \_ 2:0:0:1 sdg 8:96 [active][ready]
Quoted 6 lines
i could be off in the weeds here, but this output looks wrong. the host:channel:target:lun numbers listed there suggest your cx is indeed surfacing luns 0 and 1, but multipath is grouping them under a single target ID.
Maybe you are right! I added another LUN and this is multipath output
multipath -l
mail (36006016086f01600e46f567adb8cda11)
[size=150 GB][features="1 queue_if_no_path"][hwhandler="1 emc"] \_ round-robin 0 [active]
\_ 2:0:0:0 sdh 8:112 [active][ready]
\_ 1:0:0:0 sdb 8:16 [active][ready] \_ 1:0:0:1 sdc 8:32 [active][ready] \_ 1:0:0:2 sdd 8:48 [active][ready] \_ 2:0:0:1 sdi 8:128 [active][ready] \_ 2:0:0:2 sdj 8:144 [active][ready] \_ round-robin 0 [enabled] \_ 1:0:1:0 sde 8:64 [active][ready] \_ 1:0:1:1 sdf 8:80 [active][ready] \_ 1:0:1:2 sdg 8:96 [active][ready]
\_ 2:0:1:0 sdk 8:160 [active][ready]
\_ 2:0:1:1 sdl 8:176 [active][ready]
\_ 2:0:1:2 sdm 8:192 [active][ready]
Quoted 2 lines
i think emc engineers monitor this list; perhaps they can help.
maybe the problem is scsi_id that report the same output for all block device,
I have kernel 2.6.16-rc1 on a server and 2.6.13.5 on the other one,
with 2.6.16-rc1
lsmod
Module Size Used by dm_round_robin 3840 1 dm_emc 5760 1 dm_multipath 18696 3 dm_round_robin,dm_emc qla2400 200448 0 qla2xxx 116964 25 qla2400
with 2.6.13.5
root@server1:/home/admin# lsmod Module Size Used by ehci_hcd 29576 0 uhci_hcd 30864 0 usbcore 104828 3 ehci_hcd,uhci_hcd dm_round_robin 3712 1 dm_emc 5632 1 dm_multipath 18312 3 dm_round_robin,dm_emc qla2xxx 110044 12 firmware_class 8448 1 qla2xxx
hba controller are qlogic2462
thanks
Nicola
Quoted 16 lines
also, look at this if you havent already (there's a section on clariion cx's), and feel free to add your findings.
http://christophe.varoqui.free.fr/wiki/wakka.php?wiki=TestedEnvironments
hope that helps,
brian
--
dm-devel mailing list
[email protected]
https://www.redhat.com/mailman/listinfo/dm-devel
If I attach the a server directly to the storage I have this:
multipath -l
mail (36006016086f01600e46f567adb8cda11)
[size=150 GB][features="1 queue_if_no_path"][hwhandler="1 emc"] \_ round-robin 0 [active]
\_ 2:0:0:2 sdg 8:96 [active][ready]
\_ 2:0:0:0 sde 8:64 [active][ready]
\_ 2:0:0:1 sdf 8:80 [active][ready]
\_ round-robin 0 [enabled]
\_ 1:0:0:0 sdb 8:16 [active][ready]
\_ 1:0:0:1 sdc 8:32 [active][ready]
\_ 1:0:0:2 sdd 8:48 [active][ready]
all the tree defined LUN are grouped in the same path :-(,
maybe is a bug in qlogic driver (linux see an isp 2432 but it is a 2462) or in scsi_id what do you think about?
Nicola Murino ha scritto:
Quoted 118 lines
Brian Wong ha scritto:
Quoted 30 lines · Nicola Murino
Quoted 22 lines
Hi,
I'm trying to configure a new emc cx storage, I have the following:
2 server, each server has a qla2462 dual port hba each qla2462 is connected to a switch (only one switch) 1 emc cx storage with 4 path connected to the switch
I defined two lun on the storage however I'm able to see only one LUN
multipath -l show the following:
multipath -l
mail (36006016086f01600e46f567adb8cda11)
[size=150 GB][features="1 queue_if_no_path"][hwhandler="1 emc"] \_ round-robin 0 [active]
\_ 1:0:1:0 sdd 8:48 [active][ready]
\_ 1:0:1:1 sde 8:64 [active][ready]
\_ 2:0:1:0 sdh 8:112 [active][ready]
\_ 2:0:1:1 sdi 8:128 [active][ready]
\_ round-robin 0 [enabled]Quoted 6 lines
\_ 2:0:0:0 sdf 8:80 [active][ready] \_ 1:0:0:0 sdb 8:16 [active][ready] \_ 1:0:0:1 sdc 8:32 [active][ready] \_ 2:0:0:1 sdg 8:96 [active][ready]Quoted 6 lines
i could be off in the weeds here, but this output looks wrong. the host:channel:target:lun numbers listed there suggest your cx is indeed surfacing luns 0 and 1, but multipath is grouping them under a single target ID.
Maybe you are right! I added another LUN and this is multipath output
multipath -l
mail (36006016086f01600e46f567adb8cda11)
[size=150 GB][features="1 queue_if_no_path"][hwhandler="1 emc"] \_ round-robin 0 [active]
\_ 2:0:0:0 sdh 8:112 [active][ready]\_ 1:0:0:0 sdb 8:16 [active][ready] \_ 1:0:0:1 sdc 8:32 [active][ready] \_ 1:0:0:2 sdd 8:48 [active][ready] \_ 2:0:0:1 sdi 8:128 [active][ready] \_ 2:0:0:2 sdj 8:144 [active][ready] \_ round-robin 0 [enabled] \_ 1:0:1:0 sde 8:64 [active][ready] \_ 1:0:1:1 sdf 8:80 [active][ready] \_ 1:0:1:2 sdg 8:96 [active][ready]\_ 2:0:1:0 sdk 8:160 [active][ready]
\_ 2:0:1:1 sdl 8:176 [active][ready]
\_ 2:0:1:2 sdm 8:192 [active][ready]Quoted 2 lines
i think emc engineers monitor this list; perhaps they can help.
maybe the problem is
scsi_idthat report the same output for all block device,I have kernel 2.6.16-rc1 on a server and 2.6.13.5 on the other one,
with 2.6.16-rc1
lsmod
Module Size Used by dm_round_robin 3840 1 dm_emc 5760 1 dm_multipath 18696 3 dm_round_robin,dm_emc qla2400 200448 0 qla2xxx 116964 25 qla2400with 2.6.13.5
root@server1:/home/admin# lsmod Module Size Used by ehci_hcd 29576 0 uhci_hcd 30864 0 usbcore 104828 3 ehci_hcd,uhci_hcd dm_round_robin 3712 1 dm_emc 5632 1 dm_multipath 18312 3 dm_round_robin,dm_emc qla2xxx 110044 12 firmware_class 8448 1 qla2xxxhba controller are qlogic2462
thanks
NicolaQuoted 16 lines
also, look at this if you havent already (there's a section on clariion cx's), and feel free to add your findings.
http://christophe.varoqui.free.fr/wiki/wakka.php?wiki=TestedEnvironments
hope that helps,
brian
Signature · 3 lines
dm-devel mailing list [email protected] https://www.redhat.com/mailman/listinfo/dm-develSignature · 3 lines
dm-devel mailing list [email protected] https://www.redhat.com/mailman/listinfo/dm-devel
Quoted 29 lines · Nicola Murino
Brian Wong ha scritto:
Quoted 7 lines
i could be off in the weeds here, but this output looks wrong. the host:channel:target:lun numbers listed there suggest your cx is indeed surfacing luns 0 and 1, but multipath is grouping them under a single target ID.
Maybe you are right! I added another LUN and this is multipath output
multipath -l
mail (36006016086f01600e46f567adb8cda11)
[size=150 GB][features="1 queue_if_no_path"][hwhandler="1 emc"] \_ round-robin 0 [active]
\_ 2:0:0:0 sdh 8:112 [active][ready]\_ 1:0:0:0 sdb 8:16 [active][ready] \_ 1:0:0:1 sdc 8:32 [active][ready] \_ 1:0:0:2 sdd 8:48 [active][ready] \_ 2:0:0:1 sdi 8:128 [active][ready] \_ 2:0:0:2 sdj 8:144 [active][ready] \_ round-robin 0 [enabled] \_ 1:0:1:0 sde 8:64 [active][ready] \_ 1:0:1:1 sdf 8:80 [active][ready] \_ 1:0:1:2 sdg 8:96 [active][ready]\_ 2:0:1:0 sdk 8:160 [active][ready]
\_ 2:0:1:1 sdl 8:176 [active][ready]
\_ 2:0:1:2 sdm 8:192 [active][ready]
Quoted 5 lines
Quoted 2 lines
i think emc engineers monitor this list; perhaps they can help.
maybe the problem is
scsi_idthat report the same output for all block device,
Ah, the infamous EMC CX. There was some bug in the EMC firmware that returned a non-standard VPD page 0x83 (pre-spc3 format). You'll have to check scsi_id, it should have some fixes for it. Be sure to have the most recent version of scsi_id (resp udev) installed. It should be called with the option '-p pre-spc3-83'.
Alternatively there is always the possibility of a misconfiguration; AFAIK EMC has a setting to always return the same information for each drive; of course this should be switched off ...
Cheers,
Hannes
Signature · 4 lines
Dr. Hannes Reinecke [email protected] SuSE Linux Products GmbH S390 & zSeries Maxfeldstraße 5 +49 911 74053 688 90409 Nürnberg http://www.suse.de
Re: EMC CX LUN problem [SOLVED]
In reply to Nicola MurinoFinally I solved my problem, the gulty was scsi_id, I install CentOS and scsi_id works as expected reporting different uuid for each lun
this is my final situation:
[root@server1 block]# scsi_id -g -u -s /block/sdb36006016086f01600bc80c9afbc8dda11
[root@server1 block]# scsi_id -g -u -s /block/sdc36006016086f01600463513d9978dda11
[root@server1 block]# scsi_id -g -u -s /block/sdd36006016086f01600bc80c9afbc8dda11
[root@server1 block]# scsi_id -g -u -s /block/sde36006016086f01600463513d9978dda11
[root@server1 block]# scsi_id -g -u -s /block/sdf36006016086f01600bc80c9afbc8dda11
[root@server1 block]# scsi_id -g -u -s /block/sdg36006016086f01600463513d9978dda11
[root@server1 block]# scsi_id -g -u -s /block/sdh36006016086f01600bc80c9afbc8dda11
[root@server1 block]# scsi_id -g -u -s /block/sdi36006016086f01600463513d9978dda11
multipath -l
mail (36006016086f01600bc80c9afbc8dda11)
[size=150 GB][features="1 queue_if_no_path"][hwhandler="1 emc"] \_ round-robin 0 [active]
\_ 1:0:1:0 sdd 8:48 [active] \_ 2:0:1:0 sdh 8:112 [active] \_ round-robin 0 [enabled] \_ 1:0:0:0 sdb 8:16 [active] \_ 2:0:0:0 sdf 8:80 [active]
ql (36006016086f01600463513d9978dda11)
[size=500 GB][features="1 queue_if_no_path"][hwhandler="1 emc"] \_ round-robin 0 [active]
\_ 1:0:1:1 sde 8:64 [active] \_ 2:0:1:1 sdi 8:128 [active] \_ round-robin 0 [enabled] \_ 1:0:0:1 sdc 8:32 [active] \_ 2:0:0:1 sdg 8:96 [active]
scsi_id is broken in gentoo and ubuntu, at least for this setup infact I have a working multipath setup using gentoo with some minor difference in hardware equipment,
thanks to all,
regards
Nicola
Nicola Murino ha scritto:
Quoted 118 lines
Brian Wong ha scritto:
Quoted 30 lines · Nicola Murino
Quoted 22 lines
Hi,
I'm trying to configure a new emc cx storage, I have the following:
2 server, each server has a qla2462 dual port hba each qla2462 is connected to a switch (only one switch) 1 emc cx storage with 4 path connected to the switch
I defined two lun on the storage however I'm able to see only one LUN
multipath -l show the following:
multipath -l
mail (36006016086f01600e46f567adb8cda11)
[size=150 GB][features="1 queue_if_no_path"][hwhandler="1 emc"] \_ round-robin 0 [active]
\_ 1:0:1:0 sdd 8:48 [active][ready]
\_ 1:0:1:1 sde 8:64 [active][ready]
\_ 2:0:1:0 sdh 8:112 [active][ready]
\_ 2:0:1:1 sdi 8:128 [active][ready]
\_ round-robin 0 [enabled]Quoted 6 lines
\_ 2:0:0:0 sdf 8:80 [active][ready] \_ 1:0:0:0 sdb 8:16 [active][ready] \_ 1:0:0:1 sdc 8:32 [active][ready] \_ 2:0:0:1 sdg 8:96 [active][ready]Quoted 6 lines
i could be off in the weeds here, but this output looks wrong. the host:channel:target:lun numbers listed there suggest your cx is indeed surfacing luns 0 and 1, but multipath is grouping them under a single target ID.
Maybe you are right! I added another LUN and this is multipath output
multipath -l
mail (36006016086f01600e46f567adb8cda11)
[size=150 GB][features="1 queue_if_no_path"][hwhandler="1 emc"] \_ round-robin 0 [active]
\_ 2:0:0:0 sdh 8:112 [active][ready]\_ 1:0:0:0 sdb 8:16 [active][ready] \_ 1:0:0:1 sdc 8:32 [active][ready] \_ 1:0:0:2 sdd 8:48 [active][ready] \_ 2:0:0:1 sdi 8:128 [active][ready] \_ 2:0:0:2 sdj 8:144 [active][ready] \_ round-robin 0 [enabled] \_ 1:0:1:0 sde 8:64 [active][ready] \_ 1:0:1:1 sdf 8:80 [active][ready] \_ 1:0:1:2 sdg 8:96 [active][ready]\_ 2:0:1:0 sdk 8:160 [active][ready]
\_ 2:0:1:1 sdl 8:176 [active][ready]
\_ 2:0:1:2 sdm 8:192 [active][ready]Quoted 2 lines
i think emc engineers monitor this list; perhaps they can help.
maybe the problem is
scsi_idthat report the same output for all block device,I have kernel 2.6.16-rc1 on a server and 2.6.13.5 on the other one,
with 2.6.16-rc1
lsmod
Module Size Used by dm_round_robin 3840 1 dm_emc 5760 1 dm_multipath 18696 3 dm_round_robin,dm_emc qla2400 200448 0 qla2xxx 116964 25 qla2400with 2.6.13.5
root@server1:/home/admin# lsmod Module Size Used by ehci_hcd 29576 0 uhci_hcd 30864 0 usbcore 104828 3 ehci_hcd,uhci_hcd dm_round_robin 3712 1 dm_emc 5632 1 dm_multipath 18312 3 dm_round_robin,dm_emc qla2xxx 110044 12 firmware_class 8448 1 qla2xxxhba controller are qlogic2462
thanks
NicolaQuoted 16 lines
also, look at this if you havent already (there's a section on clariion cx's), and feel free to add your findings.
http://christophe.varoqui.free.fr/wiki/wakka.php?wiki=TestedEnvironments
hope that helps,
brian
Signature · 3 lines
dm-devel mailing list [email protected] https://www.redhat.com/mailman/listinfo/dm-develSignature · 3 lines