DISCUSSION Steffen Rose 2 participants 6 messages Apr 14, 2014 CAN network drivers

lore
Share & tools
lore
#0 lore raw

Hello,

I write a generic application, that should work with different socketcan driver implementations. I know, there are different possibilities to get the CAN controller state. And I see, that different implementation do not implement all of them.

What is the standard way to get the state change from Error Passive to Error Active?

My current way (in short incomplete form):

can_err_mask_t err_mask = CAN_ERR_FLAG | CAN_ERR_CRTL | CAN_ERR_PROT | CAN_ERR_BUSOFF; setsockopt(mBSDSocket, SOL_CAN_RAW, CAN_RAW_ERR_FILTER, &err_mask, sizeof(err_mask));

got = read(mBSDSocket, &frame, sizeof(struct can_frame)); if (frame.can_id & CAN_ERR_FLAG) {

  if (frame.can_id & CAN_ERR_PROT) {
    if (frame.data[2] & CAN_ERR_PROT_ACTIVE) {

=> change to Error active

    }

}
}

This will work with the Systec USB interface, but do not work with Peak, Beagle bone, EMS CPC. I have seen the implementation in the can utils.

I know, the libsocketcan implements a different way. But I cannot extract the relevant parts. And I think a have to poll the current state with it and I search an event based mechanism.

Signature · 3 lines
Mit freundlichen Grüßen / Regards
Steffen Rose
www.emtas.de
#1 lore raw

Hi Stefan,

Quoted 5 lines · Steffen Rose

Hello,

I write a generic application, that should work with different socketcan driver implementations.
I know, there are different possibilities to get the CAN controller

state.

Quoted 5 lines

And I see, that different
implementation do not implement all of them.

What is the standard way to get the state change from Error Passive to Error Active?

Historically we only supported "increasing" state changes "active->warning->passive->bus-off". A few recent drivers do also support "passive->warning->active" but most don't (yet).

Quoted 7 lines

My current way (in short incomplete form):

can_err_mask_t err_mask = CAN_ERR_FLAG | CAN_ERR_CRTL | CAN_ERR_PROT | CAN_ERR_BUSOFF;
setsockopt(mBSDSocket, SOL_CAN_RAW, CAN_RAW_ERR_FILTER, &err_mask, sizeof(err_mask));

Quoted 6 lines

got = read(mBSDSocket, &frame, sizeof(struct can_frame)); if (frame.can_id & CAN_ERR_FLAG) {

  if (frame.can_id & CAN_ERR_PROT) {
    if (frame.data[2] & CAN_ERR_PROT_ACTIVE) {

=> change to Error active

Yes, that would be the correct way but as I said above, only a few drivers use CAN_ERR_PROT_ACTIVE (do a "grep -r CAN_ERR_PROT_ACTIVE drivers/net/can").
...

Quoted 2 lines

This will work with the Systec USB interface, but do not work with Peak, Beagle bone, EMS CPC.

Some time ago I have posted an RFC for providing "decreasing" state changes
as well including proper bus-off recovery for the SJA1000. If would dig it out in case you are interested.

Quoted 3 lines

I have seen the implementation in the can utils.

I know, the libsocketcan implements a different way. But I cannot

extract

Quoted 2 lines

the relevant parts.
And I think a have to poll the current state with it and I search an

event

Quoted 1 line

based mechanism.

It's not a matter of libsocketcan or ip/iproute2.

Wolfgang.

#2 lore raw

Hello Wolfgang,

Quoted 6 lines
Quoted 2 lines

What is the standard way to get the state change from Error Passive to Error Active?

Historically we only supported "increasing" state changes "active->warning->passive->bus-off". A few recent drivers do also support "passive->warning->active" but most don't (yet).

Historically:
What was the correct error handling in state error passive? Did you ignore it in the application? My concrete question is, how did you "define" an error free system after this state change in earlier time?

Quoted 7 lines
Quoted 2 lines

This will work with the Systec USB interface, but do not work with Peak, Beagle bone, EMS CPC.

Some time ago I have posted an RFC for providing "decreasing" state changes
as well including proper bus-off recovery for the SJA1000. If would dig it out in case you are interested.

I'm afraid, I do not write / change my supported socketcan drivers. But I'm interested to read the RFC.

Quoted 9 lines
Quoted 7 lines

I have seen the implementation in the can utils.
I know, the libsocketcan implements a different way. But I cannot extract
the relevant parts.
And I think a have to poll the current state with it and I search an event
based mechanism.

It's not a matter of libsocketcan or ip/iproute2.

I have seen a difference of the can state between
candump -e can0,0~0,#FFFFFFFF
(increase errors - last was error passive)

and
ip -det -stat link show can0
(show error warning state)

This difference was during transmission on an open can bus with Ack error and state error passive.
ip got the correct state error passive after receiving a message later, as I did check the error active state change.

Do socketcan have different ways to get the current state? Is it a low level driver part to read and hold the current state?

(I'm sorry. I'm unsure about the driver I tested in this situation. I think, it was the EMS CPC driver and kernel 3.2.0-60-generic. )

Signature · 3 lines
Mit freundlichen Grüßen / Regards
Steffen Rose
www.emtas.de
#3 lore raw

Hi Stefan,

Quoted 3 lines · Steffen Rose

Hello Wolfgang,

Quoted 1 line
Quoted 1 line

What is the standard way to get the state change from Error Passive

to

Quoted 8 lines
Quoted 5 lines
Quoted 1 line

Error Active?

Historically we only supported "increasing" state changes "active->warning->passive->bus-off". A few recent drivers do also support "passive->warning->active" but most don't (yet).

Historically:
What was the correct error handling in state error passive? Did you

ignore

Quoted 2 lines

it
in the application? My concrete question is, how did you "define" an

error

Quoted 2 lines

free
system after this state change in earlier time?

Well, as I said. The state was never decreased from error passive, which is wrong, I agree. So far nobody cared.

Quoted 10 lines
Quoted 9 lines
Quoted 3 lines

This will work with the Systec USB interface, but do not work with Peak,
Beagle bone, EMS CPC.

Some time ago I have posted an RFC for providing "decreasing" state changes
as well including proper bus-off recovery for the SJA1000. If would dig it
out in case you are interested.

Quoted 3 lines

I'm afraid, I do not write / change my supported socketcan drivers. But I'm
interested to read the RFC.

Check

https://gitorious.org/linux-can/wg-linux-can-next/commits/eec921ac28fde243456078a557768808d93d94a3

Especially the commits for "can: sja1000: consolidate error state handling" and
"can: sja1000: consolidate bus-off handling", which can be regarded as the reference. The commit messages also shows traces. That's how they should look
like.

Quoted 4 lines
Quoted 4 lines
Quoted 4 lines

I have seen the implementation in the can utils.
I know, the libsocketcan implements a different way. But I cannot extract
the relevant parts.

libsocketcan, like ip uses a netlink socket to get the configuration and statistics of the CAN device. This includes the "state" property.

Quoted 3 lines
Quoted 3 lines
Quoted 3 lines

And I think a have to poll the current state with it and I search an event
based mechanism.

That's a bad idea. Looking to the state changes via error messages is far more elegant.

Quoted 11 lines
Quoted 1 line

It's not a matter of libsocketcan or ip/iproute2.

I have seen a difference of the can state between
candump -e can0,0~0,#FFFFFFFF
(increase errors - last was error passive)

and
ip -det -stat link show can0
(show error warning state)

This difference was during transmission on an open can bus with Ack

error

Quoted 3 lines

and
state error passive.
ip got the correct state error passive after receiving a message later,

as

Quoted 6 lines

I
did check the error active state change.

Do socketcan have different ways to get the current state? Is it a low level
driver part to read and hold the current state?

No. Both get the infos via netlink socket from the kernel.

Quoted 3 lines

(I'm sorry. I'm unsure about the driver I tested in this situation. I think,
it was the EMS CPC driver and kernel 3.2.0-60-generic. )

This device uses a SJA1000.

Wolfgang.

#4 lore raw

Hello Wolfgang,

thank you very much for your answers.

Quoted 2 lines

libsocketcan, like ip uses a netlink socket to get the configuration and statistics of the CAN device. This includes the "state" property.

Do all implementation support the netlink socket, especially the CAN state? I think, state is UNKNOWN and don't mean the Can state, is it?

$ ip -det -stat link show can0
3: can0: <NOARP,UP,LOWER_UP,ECHO> mtu 16 qdisc pfifo_fast *state* UNKNOWN qlen 
10000
    link/can 
    *can state* ERROR-ACTIVE restart-ms 0 
    bitrate 250000 sample-point 0.875 
    tq 250 prop-seg 6 phase-seg1 7 phase-seg2 2 sjw 1
    ems_usb: tseg1 1..16 tseg2 1..8 sjw 1..4 brp 1..64 brp-inc 1
    clock 8000000
    re-started bus-errors arbit-lost error-warn error-pass bus-off
    0          0          0          0          0          0         
    RX: bytes  packets  errors  dropped overrun mcast   
    0          0        0       0       0       0      
    TX: bytes  packets  errors  dropped carrier collsns 
    0          0        0       0       0       0      
Quoted 5 lines
Quoted 3 lines

Do socketcan have different ways to get the current state? Is it a low level
driver part to read and hold the current state?

No. Both get the infos via netlink socket from the kernel.

I'm not so familiar with the parts of the system and the correct naming of it.

I understand, that socketcan has a common part for all (many) driver adaptations (can_bcm, can_raw) and a CAN controller specific part (can). As I understand, for the last point exists many different implementations with different feature implementation.

Quoted 6 lines
Quoted 3 lines

(I'm sorry. I'm unsure about the driver I tested in this situation. I think,
it was the EMS CPC driver and kernel 3.2.0-60-generic. )

This device uses a SJA1000.

My mistake
USB interface from EMS

vcan                   12686  0 
can_bcm                22077  0 
can_raw                17120  0 
can                    36556  2 can_bcm,can_raw
ems_usb                17510  0 
can_dev                15321  1 ems_usb
Signature · 22 lines
Mit freundlichen Grüßen

    Steffen Rose

-------------------------------------------------------------------------

emtas - your embedded solution partner
 
Nächste CANopen Schulung am 06. Mai in Merseburg
Nächste EnergyBus Schulung am 07. Mai in Merseburg

-------------------------------------------------------------------------
emtas GmbH
Fritz-Haber-Straße 9
06217 Merseburg
Tel.:  +49(0)3461-79416-0
Fax.:  +49(0)3461-79416-10
www.emtas.de - [email protected]
Geschäftsführer: Andreas Boebel, Torsten Gedenk, Steffen Rose
Registergericht: Amtsgericht Stendal
Registernummer:  HRB 17616 
-------------------------------------------------------------------------
#5 lore raw
Quoted 5 lines · Steffen Rose

Hello Wolfgang,

thank you very much for your answers.

Quoted 1 line

libsocketcan, like ip uses a netlink socket to get the configuration

and

Quoted 3 lines
Quoted 1 line

statistics of the CAN device. This includes the "state" property.

Do all implementation support the netlink socket, especially the CAN

state?

Yes.

Quoted 4 lines

I think, state is UNKNOWN and don't mean the Can state, is it?

$ ip -det -stat link show can0
3: can0: <NOARP,UP,LOWER_UP,ECHO> mtu 16 qdisc pfifo_fast *state*

UNKNOWN

Quoted 1 line

qlen

This "state" is network related.

Quoted 1 line

10000

It follows the CAN related settings and statistics.

Quoted 4 lines

link/can
*can state* ERROR-ACTIVE restart-ms 0 bitrate 250000 sample-point 0.875
tq 250 prop-seg 6 phase-seg1 7 phase-seg2 2 sjw 1

Quoted 11 lines

ems_usb: tseg1 1..16 tseg2 1..8 sjw 1..4 brp 1..64 brp-inc 1 clock 8000000
re-started bus-errors arbit-lost error-warn error-pass bus-off
0 0 0 0 0 0
RX: bytes packets errors dropped overrun mcast
0 0 0 0 0 0
TX: bytes packets errors dropped carrier collsns
0 0 0 0 0 0

Quoted 1 line
Quoted 1 line

Do socketcan have different ways to get the current state? Is it a

low

Quoted 4 lines
Quoted 4 lines
Quoted 2 lines

level
driver part to read and hold the current state?

No. Both get the infos via netlink socket from the kernel.

This answer is wrong. It has nothing to do with the netlink socket. Sorry for confusion. Yes, the low-level driver does handle the state changes
reported by the CAN hardware.

Quoted 1 line

I'm not so familiar with the parts of the system and the correct naming

of

Quoted 4 lines

it.

I understand, that socketcan has a common part for all (many) driver adaptations (can_bcm, can_raw) and a CAN controller specific part

(can).

There is CAN protocol, common CAN devices interface and specific device drivers.

Quoted 1 line

As I understand, for the last point exists many different

implementations

Quoted 2 lines

with
different feature implementation.

Ideally they do implement the same features but it depends on the hardware to some extend, of course. The big goal is to provide a *common* interface for CAN error state and error message handling.

Quoted 10 lines
Quoted 6 lines
Quoted 3 lines

(I'm sorry. I'm unsure about the driver I tested in this situation. I think,
it was the EMS CPC driver and kernel 3.2.0-60-generic. )

This device uses a SJA1000.

My mistake
USB interface from EMS

Quoted 6 lines
vcan                   12686  0 
can_bcm                22077  0 
can_raw                17120  0 
can                    36556  2 can_bcm,can_raw
ems_usb                17510  0 
can_dev                15321  1 ems_usb

OK.

Wolfgang.