Skip to contentSkip to conversation

alsa resampler comstraints.

DISCUSSION James Courtier-Dutton 2 participants 2 messages Sep 21, 2006 – Sep 22, 2006

lore
Share & tools
lore
#0 lore raw

Hi,

I want to document some of the constraints of the alsa resampler. Here is what I understand, and I would like someone to verify my statements before I document them.

1) The buffer and period sizes for the sound card hardware to resampler are limited to the max buffer and period sizes available on the hardware. As a result, the available buffer and period sizes vary depending on hardware utilised.
2) The resampler converts one hardware period size at a time. This results in the buffer and period size constraints explained in (1) arriving at the application as a direct ratio of source and destination sample rate.
e.g. hardware has 2 periods of 1024 frames running at 48000 Hz. application will see 2 periods of 1024 * 44100 / 48000 = 940.8. This is rounded down to 940 frames. So the user application sees 2 periods of 940 frames.
If user space asks for 2 periods of 1024 at 44100 hz it will fail.

The above 2 points were true some time ago. Has anything changed?

Kind Regards

James

-------------------------------------------------------------------------
Take Surveys. Earn Cash. Influence the Future of IT
Join SourceForge.net's Techsay panel and you'll get the chance to share your opinions on IT & business topics through brief surveys -- and earn cash
http://www.techsay.com/default.php?page=join.php&p=sourceforge&CID=DEVDEV

#1 lore raw
Quoted 8 lines · James Courtier-Dutton

I want to document some of the constraints of the alsa resampler. Here is what I understand, and I would like someone to verify my statements before I document them.

1) The buffer and period sizes for the sound card hardware to resampler are limited to the max buffer and period sizes available on the hardware. As a result, the available buffer and period sizes vary depending on hardware utilised.

Yes. This is true for most of the plugins.

Quoted 4 lines

2) The resampler converts one hardware period size at a time. This results in the buffer and period size constraints explained in (1) arriving at the application as a direct ratio of source and destination sample rate.

Yes.

Quoted 1 line

The above 2 points were true some time ago. Has anything changed?

That part of the resampler hasn't changed.

Regards,
Clemens

-------------------------------------------------------------------------
Take Surveys. Earn Cash. Influence the Future of IT
Join SourceForge.net's Techsay panel and you'll get the chance to share your opinions on IT & business topics through brief surveys -- and earn cash
http://www.techsay.com/default.php?page=join.php&p=sourceforge&CID=DEVDEV