Skip to contentSkip to conversation

unclean shutdown

DISCUSSION John Levon 2 participants 2 messages Jan 24, 2007 – Jan 25, 2007

lore
Share & tools
lore

John Levon

author
#0 lore raw

Shutting down xend gives in xend.log:

[2007-01-24 11:46:09 xend 100902] DEBUG (SrvServer:76) SrvServer.cleanup()
[2007-01-24 11:46:09 xend 100902] DEBUG (XMLRPCServer:185) XMLRPCServer.cleanup() [2007-01-24 11:46:09 xend 100902] ERROR (XMLRPCServer:192) (134, 'Transport endpoint is not connected') Traceback (most recent call last):
File "/usr/lib/python2.4/site-packages/xen/xend/server/XMLRPCServer.py", line 189, in cleanup File "<string>", line 1, in shutdown
error: (134, 'Transport endpoint is not connected')

Should we be catching this and keeping quiet in this case?

regards
john

#1 lore raw
Quoted 11 lines · John Levon

Shutting down xend gives in xend.log:

[2007-01-24 11:46:09 xend 100902] DEBUG (SrvServer:76) SrvServer.cleanup()
[2007-01-24 11:46:09 xend 100902] DEBUG (XMLRPCServer:185) XMLRPCServer.cleanup() [2007-01-24 11:46:09 xend 100902] ERROR (XMLRPCServer:192) (134, 'Transport endpoint is not connected') Traceback (most recent call last):
File "/usr/lib/python2.4/site-packages/xen/xend/server/XMLRPCServer.py", line 189, in cleanup File "<string>", line 1, in shutdown
error: (134, 'Transport endpoint is not connected')

Should we be catching this and keeping quiet in this case?

Yes, we should. I've just put in a patch to catch this.

Thanks,