Wireless rates with mac80211
In mac80211, the SIOC{S,G}IWRATE commands are not implemented. Is there another way to find out what transmission rate is being used?
Larry
Quoted 3 lines · Larry Finger
In mac80211, the SIOC{S,G}IWRATE commands are not implemented. Is there another way to find out what transmission rate is being used?
If mac80211 is configured to be verbose enough, it will periodically print the average rate used since the last time the message was printed out.
#ifdef CONFIG_MAC80211_VERBOSE_DEBUG
printk(KERN_DEBUG "%s: STA " MAC_FMT " Average rate: "
"%d (%d/%d)\n",
dev->name, MAC_ARG(sta->addr),
srctrl->tx_avg_rate_sum /
srctrl->tx_avg_rate_num,
srctrl->tx_avg_rate_sum,
srctrl->tx_avg_rate_num);#endif /* CONFIG_MAC80211_VERBOSE_DEBUG */
-Michael Wu
Quoted 14 lines · Michael Wu
Quoted 3 lines · Larry Finger
In mac80211, the SIOC{S,G}IWRATE commands are not implemented. Is there another way to find out what transmission rate is being used?
If mac80211 is configured to be verbose enough, it will periodically print the average rate used since the last time the message was printed out.
#ifdef CONFIG_MAC80211_VERBOSE_DEBUG printk(KERN_DEBUG "%s: STA " MAC_FMT " Average rate: " "%d (%d/%d)\n", dev->name, MAC_ARG(sta->addr), srctrl->tx_avg_rate_sum / srctrl->tx_avg_rate_num, srctrl->tx_avg_rate_sum, srctrl->tx_avg_rate_num);
Quoted 1 line
#endif /*
CONFIG_MAC80211_VERBOSE_DEBUG*/
The problem with that level of debug, the logs are flooded with many lines each scan cycle, which happens every 1 minute with NetworkManager. In addidtion, I was hoping for something I could look at without having to peruse my way through the complete log.
Larry
Quoted 5 lines · Larry Finger
The problem with that level of debug, the logs are flooded with many lines each scan cycle, which happens every 1 minute with NetworkManager. In addidtion, I was hoping for something I could look at without having to peruse my way through the complete log.
Patches welcome. The rate control API currently has no easy way to obtain the current rate which is part of why SIOCGIWRATE hasn't been implemented yet.
-Michael Wu
Quoted 3 lines · Michael Wu
On Thursday 26 April 2007 00:16, Larry Finger wrote:
Patches welcome. The rate control API currently has no easy way to obtain the current rate which is part of why SIOCGIWRATE hasn't been implemented yet.
What is in txrate in struct sta_info? Isn't it the rate to be used for the next transmission?
Larry
Quoted 3 lines · Larry Finger
What is in txrate in struct
sta_info? Isn't it the rate to be used for the next transmission?
It is an index to the rate that could be used for the next transmission to that sta. I was referring to the rate_control_ops not having a callback that would return the current rate, but looking into sta_info should be fine. Guess I overlooked that when I was looking to implement SIOCGIWRATE. Not sure if doing this will be valid for other rate control algorithms in the future, but that can be dealt with later.
-Michael Wu
Quoted 2 lines · Larry Finger
In mac80211, the SIOC{S,G}IWRATE commands are not implemented. Is there another way to find out what transmission rate is being used?
If you have debugfs compiled in, you can look into <debugfs_mount_point>/ieee80211/phy0/stations/*/rc_simple_tx_avg_rate_[ns]um. But that's just average.
Jiri
Signature · 2 lines
Jiri Benc SUSE Labs
Quoted 4 lines · Jiri Benc
If you have debugfs compiled in, you can look into <debugfs_mount_point>/ieee80211/phy0/stations/*/rc_simple_tx_avg_rate_[ns]um. But that's just average.
Jiri,
Thanks for the info. I'm using txrate in the sta_info struct, which is an index into the rates array. That turned out to be very useful as I discovered that rc80211_simple was setting the initial rate to 54 Mbs. I have some doubt if that rate is best under any circumstance, but it certainly is not for bcm43xx as the current issues with TX power do not allow transmission at that rate. By setting the initial rate to 1 Mbs, I was able to connect for the first time with my BCM4311.
Larry
Quoted 5 lines · Larry Finger
Thanks for the info. I'm using txrate in the
sta_infostruct, which is an index into the rates array. That turned out to be very useful as I discovered thatrc80211_simplewas setting the initial rate to 54 Mbs. I have some doubt if that rate is best under any circumstance, but it certainly is not for bcm43xx as the current issues with TX power do not allow transmission at that rate. By setting the initial rate to 1 Mbs, I was able to connect for the first time with my BCM4311.
Rate control modules can be switched on-the-fly with mac80211. You can write your own rc module that uses 1 mbps all times :-) Actually, I wrote that module but haven't kept it up to date so it doesn't even compile now...
Jiri
Signature · 2 lines
Jiri Benc SUSE Labs
Quoted 5 lines · Jiri Benc
Rate control modules can be switched on-the-fly with mac80211. You can write your own rc module that uses 1 mbps all times :-) Actually, I wrote that module but haven't kept it up to date so it doesn't even compile now...
No, the simple rate algorithm is fine. Once I make the connection, it is changing the rates up and down as I would have expected. The main problem was that I never got on, and without communication there was no basis on which to adjust the rate. Now it connects reliably, which makes it a lot easier to try fixes for the power problem. It is really hard to debug a power problem when nothing works.
Larry
Quoted 3 lines · Larry Finger
No, the simple rate algorithm is fine. Once I make the connection, it is changing the rates up and down as I would have expected. The main problem was that I never got on, and without communication there was no basis on which to adjust the rate.
Hah, I had the same problem and always thought the dhcp server was somehow a bit buggy because re-doing dhcp fixed it (it sends a bunch of packets and then the rate gets adjusted down). Of course, I don't have any problems to associate since my university still runs 40-bit WEP.
johannes