Skip to contentSkip to conversation

RAMFS NOMMU: missed POSIX UID/GID inode attribute checking

PATCH New Bryan Wu 1 participant 1 message Jun 5, 2007

lore
Share & tools
lore

Bryan Wu

author
#0 lore raw

PATCH 1/1 RAMFS NOMMU: missed POSIX UID/GID inode attribute checking

From: Bryan Wu <[email protected]>

This bug was caught by LTP testcase fchmod06 on Blackfin platform.

In the manpage of fchmod, "EPERM: The effective UID does not match the owner of the file, and the process is not privileged (Linux: it does not have the CAP_FOWNER capability)."

But the ramfs nommu code missed the inode_change_ok POSIX UID/GID verification. This patch fixed this.

Cc David Howells <[email protected]>
---
 fs/ramfs/file-nommu.c |    5 +++++
 1 files changed, 5 insertions(+), 0 deletions(-)
fs/ramfs/file-nommu.c +5 -0
index 9345a46..5d258c4 100644
@@ -195,6 +195,11 @@ static int ramfs_nommu_setattr(struct dentry *dentry, struct iattr *ia)
 	unsigned int old_ia_valid = ia->ia_valid;
 	int ret = 0;
 
+	/* POSIX UID/GID verification for setting inode attributes */
+	ret = inode_change_ok(inode, ia);
+	if (ret)
+		return ret;
+
 	/* by providing our own setattr() method, we skip this quotaism */
 	if ((old_ia_valid & ATTR_UID && ia->ia_uid != inode->i_uid) ||
 	    (old_ia_valid & ATTR_GID && ia->ia_gid != inode->i_gid))
Signature · 1 line
1.5.2