RHEL5 and RDAC/Multipath
Hi,
We've bought and IBM BladecenterH and IBM DS4700 storage.
We are using Redhat Enterprise Linux 5 and we are trying to put multipath working.
RHEL5 we are using uses 2.6.18-8.1.3.el5xen. We've ported rdac patch
(http://kernel.org/pub/linux/kernel/people/agk/patches/2.6/2.6.21/dm-mpath-rdac.patch)
to RHEL5 kernel. We've also updated multipath-tools to support mpath_prio_rdac.
Our multipath.conf is:
devnode_blacklist {
devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*" devnode "^hd[a-z]"
devnode "^cciss!c[0-9]d[0-9]*"
#USB 4G Flash drive inside HS21
devnode "sda"
}
defaults {
multipath_tool "/sbin/multipath -v0"
udev_dir /dev
polling_interval 5
default_selector "round-robin 0" default_getuid_callout "/sbin/scsi_id -g -u -s /block/%n" #default_prio_callout "/bin/true"
failback immediate
path_checker rdac
hardware_handler "1 rdac"
prio_callout "/sbin/mpath_prio_tpc /dev/%n" path_grouping_policy group_by_prio
}
multipaths {
multipath {
wwid 3600a0b8000320bea0000048f46e52137 alias client_data
}
}
When we start multipath -v2 it creates multipath devices. I can see 2 active paths (active controler) and 2 ghost paths (standby controler). When i unplug 2 active fibre that connect the fabric to DS4700, multipath reports I/O errors and doesn't failover the controler.
Any ideas?
Thanks for any help
Nuno Fernandes
Could you try using in your default settings
no_path_retry queue
Regards
Sunil Joshi
Quoted 61 lines · Nuno Fernandes
Hi,
We've bought and IBM BladecenterH and IBM DS4700 storage.
We are using Redhat Enterprise Linux 5 and we are trying to put multipath working.RHEL5 we are using uses 2.6.18-8.1.3.el5xen. We've ported rdac patch (
http://kernel.org/pub/linux/kernel/people/agk/patches/2.6/2.6.21/dm-mpath-rdac.patch
)
to RHEL5 kernel. We've also updated multipath-tools to supportmpath_prio_rdac.Our multipath.conf is:
devnode_blacklist{
devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*" devnode "^hd[a-z]"
devnode "^cciss!c[0-9]d[0-9]*"
#USB 4G Flash drive inside HS21
devnode "sda"
}defaults {
multipath_tool"/sbin/multipath-v0"
udev_dir/dev
polling_interval5
default_selector"round-robin 0"default_getuid_callout"/sbin/scsi_id-g -u -s /block/%n" #default_prio_callout "/bin/true"
failback immediate
path_checkerrdac
hardware_handler"1 rdac"
prio_callout"/sbin/mpath_prio_tpc/dev/%n"path_grouping_policygroup_by_prio
}multipaths {
multipath {
wwid3600a0b8000320bea0000048f46e52137
aliasclient_data
}
}When we start multipath -v2 it creates multipath devices. I can see 2 active
paths (active controler) and 2 ghost paths (standby controler). When i unplug 2 active fibre that connect the fabric to DS4700, multipath reports I/O errors and doesn't failover the controler.Any ideas?
Thanks for any help
Nuno Fernandes--
dm-devel mailing list
[email protected]
https://www.redhat.com/mailman/listinfo/dm-devel
Hi Nuno,
I would suggest you to move the rdac specific configuration information to device section and retry.
Are you running the multipathd command ?
Here is how my rdac configuration looks in multipath.conf
--------------------------
devices {
device {
vendor "IBM"
product "1815"
hardware_handler "1 rdac"
path_checker rdac
failback immediate
path_grouping_policy group_by_prio
prio_callout "/sbin/mpath_prio_tpc /dev/%n"
}
}
-----------------------------
Let me know how it goes,
chandra
Quoted 56 lines · Nuno Fernandes
Hi,
We've bought and IBM BladecenterH and IBM DS4700 storage.
We are using Redhat Enterprise Linux 5 and we are trying to put multipath working.RHEL5 we are using uses 2.6.18-8.1.3.el5xen. We've ported rdac patch
(http://kernel.org/pub/linux/kernel/people/agk/patches/2.6/2.6.21/dm-mpath-rdac.patch)
to RHEL5 kernel. We've also updated multipath-tools to supportmpath_prio_rdac.Our multipath.conf is:
devnode_blacklist { devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*" devnode "^hd[a-z]" devnode "^cciss!c[0-9]d[0-9]*" #USB 4G Flash drive inside HS21 devnode "sda" }defaults {
multipath_tool"/sbin/multipath-v0"
udev_dir/dev
polling_interval5
default_selector"round-robin 0"
default_getuid_callout"/sbin/scsi_id-g -u -s /block/%n"
#default_prio_callout "/bin/true"
failback immediate
path_checkerrdac
hardware_handler"1 rdac"
prio_callout"/sbin/mpath_prio_tpc/dev/%n"
path_grouping_policygroup_by_prio
}multipaths { multipath { wwid 3600a0b8000320bea0000048f46e52137 alias client_data } }When we start multipath -v2 it creates multipath devices. I can see 2 active paths (active controler) and 2 ghost paths (standby controler). When i unplug 2 active fibre that connect the fabric to DS4700, multipath reports I/O errors and doesn't failover the controler.
Any ideas?
Thanks for any help
Nuno Fernandes--
dm-devel mailing list
[email protected]
https://www.redhat.com/mailman/listinfo/dm-devel
Signature · 4 lines
----------------------------------------------------------------------
Chandra Seetharaman | Be careful what you choose....
- [email protected] | .......you may get it.
----------------------------------------------------------------------Hi,
It's working. For IBM DS4700 i only had to change in the multipath.conf
vendor "IBM"
product "1814*"
I didn't try it but shouln't be using prio_callout /sbin/mpath_prio_rdac??
Thanks
Nuno Fernandes
Quoted 83 lines · On Monday 24 September 2007 19:30:31 Chandra Seetharaman wrote:
Hi Nuno,
I would suggest you to move the rdac specific configuration information to device section and retry.
Are you running the multipathd command ?
Here is how my rdac configuration looks in multipath.conf
--------------------------
devices {
device {
vendor "IBM"
product "1815"
hardware_handler"1 rdac"
path_checkerrdac
failback immediate
path_grouping_policygroup_by_prio
prio_callout"/sbin/mpath_prio_tpc/dev/%n"
}
}
-----------------------------
Let me know how it goes,chandra
Quoted 57 lines · Nuno Fernandes
Hi,
We've bought and IBM BladecenterH and IBM DS4700 storage.
We are using Redhat Enterprise Linux 5 and we are trying to put multipath working.RHEL5 we are using uses 2.6.18-8.1.3.el5xen. We've ported rdac patch
(http://kernel.org/pub/linux/kernel/people/agk/patches/2.6/2.6.21/dm-mpat
h-rdac.patch) to RHEL5 kernel. We've also updated multipath-tools to supportmpath_prio_rdac.Our multipath.conf is:
devnode_blacklist { devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*" devnode "^hd[a-z]" devnode "^cciss!c[0-9]d[0-9]*" #USB 4G Flash drive inside HS21 devnode "sda" }defaults {
multipath_tool"/sbin/multipath-v0"
udev_dir/dev
polling_interval5
default_selector"round-robin 0"
default_getuid_callout"/sbin/scsi_id-g -u -s /block/%n"
#default_prio_callout "/bin/true"
failback immediate
path_checkerrdac
hardware_handler"1 rdac"
prio_callout"/sbin/mpath_prio_tpc/dev/%n"
path_grouping_policygroup_by_prio
}multipaths { multipath { wwid 3600a0b8000320bea0000048f46e52137 alias client_data } }When we start multipath -v2 it creates multipath devices. I can see 2 active paths (active controler) and 2 ghost paths (standby controler). When i unplug 2 active fibre that connect the fabric to DS4700, multipath reports I/O errors and doesn't failover the controler.
Any ideas?
Thanks for any help
Nuno Fernandes--
dm-devel mailing list
[email protected]